| поискавой системы для электроныых деталей |
|
AS8220 датащи(PDF) 18 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS8220 датащи(HTML) 18 Page - ams AG |
|
18 / 34 page ![]() www.austriamicrosystems.com Revision 17920-001-10a 17 - 33 AS8220A Objective Data Sheet - Detailed Description High current on BM high side driver This flag can only be set/reset in NORMAL mode when the driver is enabled and during the transmission of a stable Data0 longer than tBUS_ERROR. If the absolute value of the BM pin current is higher than ITHH after tBUS_ERROR since the driver enable signal then the flag is set otherwise it is reset. The flag is reset at power off. High current on BM low side driver This flag can only be set/reset in NORMAL mode when the driver is enabled and during the transmission of a stable Data1 longer than tBUS_ERROR. If the absolute value of the BM pin current is higher than ITHH after tBUS_ERROR since the driver enable signal then the flag is set otherwise it is reset. The flag is reset at power off. BP open line This flag is the logical “AND” between: low current on BP high side and low current on BP low side. BM open line This flag is the logical “AND” between: low current on BM high side and low current on BM low side. BP short circuit to VCC This flag is the logical “AND” between: low current on BP high side and high current on BP low side. BP short circuit to GND This flag is the logical “AND” between: high current on BP high side and low current on BP low side. BM short circuit toVCC This flag is the logical “AND” between: low current on BM high side and high current on BM low side. BM short circuit to GND This flag is the logical “AND” between: high current on BM high side and low current on BM low side. Short circuit between BP and BM This flag can only be set or reset in NORMAL mode when the driver is enabled. After a time tBUS_ERROR since TxD edge if the absolute value of the differential bus voltage is lower than VSHORT then the flag is set otherwise it is reset. he flag is reset at power off. Over temperature This flag can only be set or reset in the non low power modes. The flag is set when the junction temperature exceeds OTTH and it is reset when the junction temperature falls below OTTL. TxEN_BGE timeout This flag can only be set in NORMAL mode when the driver is enabled (TxEN is low and BGE is high) for a time longer than tTxEN_max. It is reset every transition on TxEN or BGE or if the device exits NORMAL mode. If the flag is set the driver is disabled. Error flag This flag is set if at least one error flag or if VIO flag is set and it is reset if none of the previous flag is set. Status Flags Description Power on flag The power on flag is set leaving the power off state and it is reset entering a low power mode after a non low power mode. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |