| поискавой системы для электроныых деталей |
|
OT40F3 датащи(PDF) 13 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
OT40F3 датащи(HTML) 13 Page - List of Unclassifed Manufacturers |
|
13 / 72 page ![]() 13 1SCC301001C0201 Technical data Size A 20 30 40 60 80 30 60 100 100 200 400 600 Switch type OT16_ OT25_ OT40_ OT63_ OT80_ OT30_ OT60 OT100_ OT160_ OT200_U OT400_U OT600_U Approvals1) 2 pole UL 98 & IEC UL 98 & IEC UL 98 & IEC UL 98 & IEC 3 pole UL508 & IEC UL508 & IEC UL508 & IEC UL508 & IEC UL508 & IEC UL 98 & IEC UL 98 & IEC UL 98 & IEC UL 98 & IEC UL 98 & IEC UL 98 & IEC UL 98 & IEC 4 pole UL508 & IEC UL508 & IEC UL508 & IEC UL508 & IEC UL508 & IEC UL 98 & IEC UL 98 & IEC UL 98 & IEC UL 98 & IEC UL 98 & IEC UL 98 & IEC UL 98 & IEC Technical data according to UL/CSA AC ratings General purpose amp rating pf= 0.7...0.8 -40° to 40 °C A 20 30 40 60 80 30 60 100 100 200 400 600 Max. oprerating voltage V 600 600 600 600 600 600 600 600 600 600 600 600 Max. horsepower rating /motor FLA current pf= 04...0.5 240 V HP/A 5/15.2 7.5/22.0 10/28.0 15/42.0 20/54.0 10/28.0 20/54.0 30/80.0 40/104.0 75/192.0 125/312.0 200/480.0 Three phase 480 V HP/A 10/14.0 15/21.0 20/27.0 30/40.0 40/52.0 20/27.0 40/52.0 50/65.0 75/96.0 150/180.0 250/302.0 450/515.0 600 V HP/A 15/17 20/22.0 25/27.0 30/32.0 40/41.0 30/32.0 40/41.0 50/52.0 100/99.0 200/192.0 350/336.0 500/472.0 Single phase 120 V HP/A 1/16.0 1.5/20.0 2/24.0 2/24.0 2/24.0 2/24.0 3/34.0 5/56.0 7.5/80.0 240 V HP/A 2/13.2 3/18.7 5/30.8 7.5/40.0 10/57.5 5/28.0 7.5/40.0 15/68.0 20/88.0 Short circuit rating with fuse Maximum fuse size A 30 602) 30 602) 30 602) 100 150 100 150 60 150 150 200 200 400 600 600 800 Fuse type CC kA 10 10 10 Fuse type J kA 10 10 10 10 10 10 100 100 50 50 50 100 200 65 100 100 Fuse type T kA 10 10 10 10 10 10 100 100 50 50 50 100 Fuse type RK1 kA 10 10 10 Fuse type RK5 kA 5 5 5 5 5 5 10 5 10 5 100 Fuse type L kA 100 Fuse type H kA 5 5 Maximum General Use DC ratings Current rating at 250VDC A 200 400 600 at 600VDC A 100 200 200 DC horsepower rating for 4-pole switch at 600VDC HP 50 50 - DC horsepower rating for 2-pole switch at 125VDC HP 20 40 - at 250VDC HP - 50 50 DC short circuit rating for 4-pole switch with circuit breaker kA 10 10 10 DC short circuit rating for 2-pole switch with circuit breaker at 250VDC kA 14 14 18 with circuit breaker at 600VDC kA 10 10 10 with Calss J fuse at 250VDC kA 100 100 100 ... with fuse size A 200 400 600 Endurances Min. electrical endurance, pf. 0,75 - 0,8 oper. cycles 6 000 6 000 6 000 6 000 6 000 6 000 6 000 6 000 6 000 6 000 1 000 1 000 Mechanical endurance operations 20 000 20 000 20 000 20 000 20 000 20 000 20 000 20 000 20 000 20 000 16 000 10 000 Terminal lug kits integral integral integral integral integral integral integral integral integral OZXA-200 OZXA-400 OZXA-800 Wire range AWG 18-8 18-8 18-8 14-4 14-4 14-4 14-4 8-1/0 8-1/0 4-300MCM 2-600MCM 2x2-600MCM Torgue Wire tightening lg. in. 7 7 7 18 18 55 55 55 70 275 375 500 Lug mounting 72 240 480 Technical data according to IEC 60947-3 Rated insulation voltage and rated operational voltage AC20/DC20 Pollution degree 3 V 750 750 750 750 750 750 750 750 750 1 000 1 000 1 000 Dielectric strength 50 Hz 1min. kV 6 6 6 6 6 6 6 6 10 10 10 10 Rated impulse withstand voltage kV 8 8 8 8 8 8 8 8 12 12 12 12 Rated operational current, AC-22A up to 415 V A 16 25 40 63 80 40 63 100 2003) 250 400 800 440 - 500 V A 16 25 40 63 80 40 63 100 160 250 400 800 690 V A 16 25 40 63 80 40 63 100 160 250 400 800 Rated operational current, AC-23A up to 415 V A 16 20 23 45 75 40 63 80 135 250 400 800 440 V A 16 20 23 45 65 40 63 65 125 250 400 800 500 V A 16 20 23 45 58 40 63 60 125 250 400 800 690 V A 10 11 12 20 20 40 40 40 80 250 400 800 Rated conditional short-circuit current I p (r.m.s.) and corresponding I p (r.m.s.) 50 kA kA 6.5 6.5 6.5 13 13 16.5 16.5 16.5 max. allowed cut-off current î c Max. OFA_ fuse size gG/aM 415 V A 40/32 40/32 40/32 100/80 100/80 125/125 125/125 125/125 The cut-off current î c refers to values I p (r.m.s.) 10 kA kA 8.2 8.2 8.2 listed by fuse manufacturers Max. OFA_ fuse size gG/aM 690 V A 125/100 125/100 125/100 (single phase test acc. to IEC60269) I p (r.m.s.) 50 kA kA 4 4 4 11 11 10 10 10 24 35 50.5 71.5 Max. OFA_ fuse size gG/aM 690 V A 25/16 25/16 25/16 80/63 80/63 63/63 63/63 63/63 200/250 355/315 500/500 800/1 000 at prospective SC-current Max. OFA_fuse size gG/aM 80 kA 690 V kA A 40.5 355/315 59 500/500 83.5 800/1 000 Rated short-time withstand current r.m.s. -value I cw 690V, 1s kA 0.5 0.5 0.5 1 1.5 2.5 2.5 2.5 4 8 15 20 Rated short circuit making capacity Peak value Icm 690V/500V kA 0.705 0.705 0.705 1.4 2.1 3.6 3.6 3.6 12 30 65 80 Power loss / pole At rated operational current W 0.3 0.6 1.6 2.8 4.5 0.7 1.6 4.0 6.5 6.5 10 40 Mechanical endurance Divide by two for operation cycles Oper. 20 000 20 000 20 000 20 000 20 000 20 000 20 000 20 000 20 000 20 000 16 000 10 000 Weight without accessories 3-pole kg 0.11 0.11 0.11 0.27 0.27 0.36 0.36 0.36 1.1 1.2 2.2 5.2 4-pole kg 0.15 0.15 0.15 0.35 0.35 0.50 0.50 0.50 1.3 1.5 2.8 6.4 Non fusible disconnect switches OT 16...600 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |