| поискавой системы для электроныых деталей |
|
MP5000 датащи(PDF) 10 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MP5000 датащи(HTML) 10 Page - Monolithic Power Systems |
|
10 / 12 page ![]() MP5000 – 12V, 1A-5A PROGRAMMABLE CURRENT LIMIT SWITCH MP5000 Rev. 1.41 www.MonolithicPower.com 10 9/6/2013 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2013 MPS. All Rights Reserved. 3. A thermal fault will cause a mid level on the Enable/Fault pin, and will set the fault flag. The Enable/Fault line must be above the mid level for the output to be turned on. The fault flag is an internal flip-flop that can be set or reset under various conditions: 1. Thermal Shutdown: set fault flag 2. Under Voltage: reset fault flag 3. low voltage on Enable/Fault pin: reset fault flag 4. mid voltage on Enable/Fault pin: no effect Under a fault, the Enable/Fault pin is driven to the mid level. There are 4 types of faults, and each fault has a direct and indirect effect on the Enable/Fault pin and the internal fault flag. In a typical application there are one or more of the MP5000 (or MP5001) chips in a system. The Enable/Fault lines will typically be connected together. Table 3 —Fault Function Influence in Application Fault description Internal action Effect on Fault Pin Effect on Flag Effect on secondary Part Short/over current Limit current none none none Under Voltage Output is turned off Internally drives Enable/Fault pin to Logic low Flag is reset Secondary part output is disabled, and fault flag is reset. Over Voltage Limit output voltage None None None Thermal Shutdown Shutdown part. The part is latched off until a UVLO or externally driven to ground. Internally drives Enable/Fault pin to mid level Flag is set Secondary part output is disabled. UNDER VOLTAGE LOCK OUT OPERATION If the supply (input) is below the UVLO threshold, the output is disabled, and the fault line is driven low. When the supply goes above the UVLO threshold, the output is enabled and the fault line is released. When the fault line is released it will be pulled high by a 25uA current source. No external pull up resistor is required. In addition, the pull up voltage is limited to 5 volts. THERMAL PROTECTION When thermal protection is detected, the output is disabled and the fault line is driven to the mid level. The thermal fault condition is latched (meaning the fault flag is set), and the part will remain latched off until the fault (enable) line is brought low. Cycling the power below the UVLO threshold will also reset the fault flag. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |