12 / 17 page ![]() MP4012 ─ HIGH-VOLTAGE, HIGH-CURRENT ACCURACY WLED CONTROLLER MP4012 Rev. 1.12 www.MonolithicPower.com 12 10/12/2013 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2013 MPS. All Rights Reserved. The hiccup time of Over Current Protection (Figure 3) can be approximately calculated as: COMP hiccup C Z 9V-V t(C C ) 5A ≈ + μ Here, VCOMP is the voltage of COMP when fault condition is detected. The hiccup time of Over Voltage Protection (Figure 4) can be approximately calculated as: delay OVP1 OVP2 O t0.1 (R R ) C ≈ ×+ × COMP hiccup1 C Z 9V-V t(C C ) 5A ≈ + μ hiccup2 C Z 8V t(C C ) 5A ≈ + μ |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|