17 / 33 page ![]() INA226 www.ti.com SBOS547 – JUNE 2011 Simple Current Shunt Monitor Usage (No Programming Necessary) The INA226 can be used without any programming if it is only necessary to read a shunt voltage drop and bus voltage with the default power-on reset configuration and continuous conversion of shunt and bus voltage. Without programming the INA226 Calibration Register, the device is unable to provide either a valid current or power value, because these outputs are both derived using the values loaded into the Calibration Register. Default INA226 Settings The default power-up states of the registers are shown in the INA226 Register Descriptions section of this data sheet. These registers are volatile, and if programmed to a value other than the default values shown in Table 2, they must be re-programmed at every device power-up. Detailed information on programming the Calibration Register specifically is given in the Configure/Measure/Calculate Example section and calculated based on Equation 1. REGISTER INFORMATION The INA226 uses a bank of registers for holding configuration settings, measurement results, minimum/maximum limits, and status information. Table 2 summarizes the INA226 registers; refer to Figure 1 for an illustration of the registers. Table 2. Summary of Register Set POINTER ADDRESS POWER-ON RESET HEX REGISTER NAME FUNCTION BINARY HEX TYPE(1) All-register reset, shunt voltage and bus 0 Configuration Register voltage ADC conversion times and 01000001 00100111 4127 R/W averaging, operating mode. 1 Shunt Voltage Shunt voltage measurement data. 00000000 00000000 0000 R 2 Bus Voltage Bus voltage measurement data. 00000000 00000000 0000 R Contains the value of the calculated 3 Power(2) 00000000 00000000 0000 R power being delivered to the load. Contains the value of the calculated 4 Current(2) current flowing through the shunt 00000000 00000000 0000 R resistor. Sets full-scale range and LSB of current 5 Calibration and power measurements. Overall 00000000 00000000 0000 R/W system calibration. Alert configuration and conversion ready 6 Mask/Enable 00000000 00000000 0000 R/W flag. Contains the limit value to compare to 7 Alert Limit 00000000 00000000 0000 R/W the selected Alert function. Contains unique die identification FF Die ID ASCII ASCII R number. (1) Type: R = Read-Only, R/W = Read/Write. (2) The Current Register defaults to '0' because the Calibration Register defaults to '0', yielding a zero current and power value until the Calibration Register is programmed. Copyright © 2011, Texas Instruments Incorporated Submit Documentation Feedback 17 Product Folder Link(s): INA226 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |