22 / 32 page ![]() REV. A AD9848/AD9849 –22– UP TO FOUR INDIVIDUAL HORIZONTAL CLAMP AND BLANKING REGIONS MAY BE PROGRAMMED WITHIN A SINGLE FIELD, USING THE SEQUENCE CHANGE POSITIONS. SEQUENCE CHANGE OF POSITION #1 SEQUENCE CHANGE OF POSITION #2 SEQUENCE CHANGE OF POSITION #3 SINGLE FIELD (1 VD INTERVAL) CLAMP AND PBLK SEQUENCE REGION 0 SEQUENCE CHANGE OF POSITION #0 (V-COUNTER = 0) CLAMP AND PBLK SEQUENCE REGION 3 CLAMP AND PBLK SEQUENCE REGION 2 CLAMP AND PBLK SEQUENCE REGION 1 Figure 12. Clamp and Blanking Sequence Flexibility Table IV. CLPOB, CLPDM, PBLK Individual Sequence Parameters Register Name Length Range Description SPOL 1b High/Low Starting Polarity of Clamp and Blanking Pulses for Sequences 0–3 TOG1 12b 0–4095 Pixel Location First Toggle Position within the Line for Sequences 0–3 TOG2 12b 0–4095 Pixel Location Second Toggle Position within the Line for Sequences 0–3 Table V. HBLK Individual Sequence Parameters Register Name Length Range Description HBLKMASK 1b High/Low Masking Polarity for H1 for Sequences 0–3 (0 = H1 Low, 1 = H1 High) HBLKTOG1 12b 0–4095 Pixel Location First Toggle Position within the Line for Sequences 0–3 HBLKTOG2 12b 0–4095 Pixel Location Second Toggle Position within the Line for Sequences 0–3 Table VI. Horizontal Sequence Control Parameters for CLPOB, CLPDM, PBLK, and HBLK Register Name Length Range Description SCP1–SCP3 12b 0–4095 Line Number CLAMP/BLANK SCP to Define Horizontal Regions 0–3 SPTR0–SPTR3 2b 0–3 Sequence Number Sequence Pointer for Horizontal Regions 0–3 H-Counter Synchronization The H-Counter reset occurs on the sixth CLI rising edge following the HD falling edge. The PxGA steering is synchronized with the reset of the internal H-Counter (see Figure 13). 000 1 12 111 0 03 11 00 01234 5 6 7 89 10 11 12 14 15 01 2 3 02 3 4 H-COUNTER RESET VD NOTES 1. INTERNAL H-COUNTER IS RESET ON THE SIXTH CLI RISING EDGE FOLLOWING THE HD FALLING EDGE. 2. PxGA STEERING IS SYNCRONIZED WITH THE RESET OF THE INTERNAL H-COUNTER (MOSAIC SEPARATE MODE IS SHOWN). 3. VD FALLING EDGE SHOULD OCCUR ONE CLOCK CYCLE BEFORE HD FALLING EDGE FOR PROPER PxGA LINE SYNCHRONIZATION. HD XX XX X X X PxGA GAIN REGISTER CLI XX XX X X X H-COUNTER (PIXEL COUNTER) 3ns MIN 23 5 3ns MIN X X Figure 13. H-Counter Synchronization |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |