| поискавой системы для электроныых деталей |
|
WLD2 датащи(PDF) 41 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
WLD2 датащи(HTML) 41 Page - Omron Electronics LLC |
|
41 / 42 page ![]() WL WL 41 Precautions Cautions When a rod or wired-type actuator is used, do not touch the top end of the actuator. Doing so may result in injury. Applicable models: WLHAL5 and WL01HAL5 Rod Spring Levers and WLNJ-S2 and WL01NJ-S2 Steel-wire Actuators. Correct Use A short-circuit may cause damage to the Switch, so insert a circuit breaker fuse, of 1.5 to 2 times the rated current, in parallel with the Switch. In order to meet EN approval ratings, use a 10-A fuse that corresponds to IEC269, either a gI or gG. When wiring terminal screws, use M4 round crimp terminals and tighten screws to the recommended torque. Wiring with broken wires, or the incorrect crimp terminals, or not tightening screws to the recommended torque can lead to short-circuits, leakage cur- rent, and fire. When performing internal wiring there is a chance of short-circuit, leakage current, or fire, so be sure to protect the inside of the Switch from splashes of oil or water, corrosive gases, and cutting powder. Using an inappropriate connector or assembling Switches incor- rectly (assembly, tightening torque) can result in malfunction, leak- age current, or fire, so be sure to read the instruction manual thor- oughly beforehand. Even when the connector is assembled and set correctly, the end of the cable and the inside of the Switch may come in contact. This can lead to malfunction, leakage current, or fire, so be sure to protect the end of the cable from splashes of oil or water and corrosive gases. Environmental Precautions When the Switch is used in locations subject to splashes of water or oil, the material of the seal, which ensures the sealing properties of the Switch, may undergo changes in shape and quality. This is due to deterioration (including expansion and contraction), and may re- sult in reduced performance, ineffective return, and ineffective seal- ing (leading to ineffective contact, insulation, leakage current, and fire). Confirm the possible effects of the operating environment on the Switch before use. Built-in Switch Do not remove or replace the built-in switch. If the position of the built-in switch moves, it can cause reduced performance, and if the insulation sheet moves (separator), the insulation may become in- effective. Correct Tightening Torque If screws are too loose they can lead to an early malfunction of the Switch, so ensure that all screws are tightened using the correct torque. No. Type Torque A Head mounting screw 0.78 to 0.88 N S m B Cover mounting screw 1.18 to 1.37 N S m C Allen-head bolt (for securing the lever) 4.90 to 5.88 N S m D Terminal screw 0.59 to 0.78 N S m E Connector 1.77 to 2.16 N S m F Main Unit screws 4.90 to 5.88 N S m In particular, when changing the direction of the Head, make sure that all screws are tightened again to the correct torque. Do not al- low foreign objects to fall into the Switch. Installing the Switch To install the Switch, make a mounting panel, as shown in the follow- ing diagram, and tighten screws using the correct torque. Standard/Overtravel model Overtravel model (side installation) Mounting holes Four, 5.2 +0.2 0 dia. holes Mounting holes Two, 5.2 +0.2 0 dia. holes |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |