| поискавой системы для электроныых деталей |
|
L99MC6 датащи(PDF) 14 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L99MC6 датащи(HTML) 14 Page - STMicroelectronics |
|
14 / 55 page ![]() Description L99MC6 14/55 Doc ID 16523 Rev 1 2.4.1 Direct input IN/PWM The IN/PWM input allows channel 2 to be enabled without the use of SPI. The IN/PWM pin is OR-ed with the SPI command bit. This pin can be left open if the channel 2 is controlled only via the SPI. This input has an internal pull-down. The IN/PWM signal can also be applied to any other switches by the activation of the PWM mode. This input is suited for non-inductive loads that are pulse width modulated. This allows PWM control without further use of the SPI. 2.4.2 Temperature warning and thermal shutdown If the junction temperature rises above Tj TW a temperature warning flag is set and is detectable via the SPI. If the junction temperature increases above the second threshold TjSD, the thermal shutdown bit is set and power DMOS transistors of all output stages are switched-off to protect the device. Temperature warning flag and thermal shutdown bits are latched. In order to reactivate the output stages, the junction temperature must decrease below TjSD- TjSDHYS and the thermal shutdown bit has to be cleared by the microcontroller. 2.4.3 Open-load detection in off-state The open-load detection monitors the load at each output stage in off mode. A current source of 150 µA (IOLD1-6, IOLS 1-3) is connected between drain and source or GND. An open-load failure is detected if the drain or source voltage reaches an internal VOLD/S (2.0 V) for at least 3 ms (tdOL typ.). The corresponding open-load bit is set in the status register. In LED mode the open-load detection is disabled and the current source is switched-off, which avoids a turn-on of the LEDs in off-state. 2.4.4 Overload detection In case of an overcurrent condition, a flag is set in the corresponding status register. If the overcurrent signal is valid for at least tISC = 32 µs, the overcurrent flag is set and the corresponding driver is switched-off to reduce the power dissipation and to protect the integrated circuit. If the overcurrent recovery bit of the output is zero the microcontroller has to clear the status bit to reactivate the corresponding driver. 2.5 Bridge mode The L99MC6 can be configured as bridge driver. Up to three half bridges can be used. In Bridge mode the device is crosscurrent protected by an internal delay time. If one driver (LS or HS) is turned-off the activation of the other driver of the same half bridge is automatically delayed by the crosscurrent protection time. After the crosscurrent protection time is expired the slew rate limited switch-off phase of the driver is changed to a fast turn-off phase and the opposite driver is turned-on with slew-rate limitation. Due to this behavior it is always guaranteed that the previously activated driver is totally turned-off before the opposite driver starts to conduct. Due to the built-in reverse diodes of the output transistors, inductive loads can be driven at the outputs without external free-wheeling diodes. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |