7 / 16 page ![]() Data Sheet ADuM5010 Rev. A | Page 7 of 16 DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS These isolators are suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by the protective circuits. The asterisk (*) marking on packages denotes DIN V VDE V 0884-10 approval. Table 11. VDE Characteristics Description Test Conditions/Comments Symbol Characteristic Unit Installation Classification per DIN VDE 0110 For Rated Mains Voltage ≤ 150 V rms I to IV For Rated Mains Voltage ≤ 300 V rms I to III For Rated Mains Voltage ≤ 400 V rms I to II Climatic Classification 40/105/21 Pollution Degree per DIN VDE 0110, Table 1 2 Maximum Working Insulation Voltage VIORM 560 V peak Input-to-Output Test Voltage, Method b1 VIORM × 1.875 = Vpd(m), 100% production test, tini = tm = 1 sec, partial discharge < 5 pC Vpd(m) 1050 V peak Input-to-Output Test Voltage, Method a After Environmental Tests Subgroup 1 VIORM × 1.5 = Vpd(m), tini = 60 sec, tm = 10 sec, partial discharge < 5 pC Vpd(m) 840 V peak After Input and/or Safety Test Subgroup 2 and Subgroup 3 VIORM × 1.2 = Vpd(m), tini = 60 sec, tm = 10 sec, partial discharge < 5 pC Vpd(m) 672 V peak Highest Allowable Overvoltage VIOTM 3535 V peak Surge Isolation Voltage VIOSM(TEST) = 10 kV, 1.2 µs rise time, 50 µs, 50% fall time VIOSM 4000 V peak Safety Limiting Values Maximum value allowed in the event of a failure Case Temperature (see Figure 2) TS 150 °C Safety Total Dissipated Power IS1 2.5 W Insulation Resistance at TS VIO = 500 V RS >109 Ω 0 0.5 1.0 1.5 2.0 2.5 3.0 0 50 100 150 200 AMBIENT TEMPERATURE (°C) Figure 2. Thermal Derating Curve, Dependence of Safety Limiting Values on Case Temperature, per DIN V VDE V 0884-10 RECOMMENDED OPERATING CONDITIONS Table 12. Parameter Symbol Min Max Unit Operating Temperature1 TA −40 +105 °C Supply Voltages2 VDD1 at VSEL = 0 V VDD 3.0 5.5 V VDD1 at VSEL = VISO 4.5 5.5 V 1 Operation at 105°C requires reduction of the maximum load current as specified in Table 13. 2 Each voltage is relative to its respective ground. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |