14 / 37 page ![]() PCT2075 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2013. All rights reserved. Product data sheet Rev. 3 — 21 May 2013 14 of 37 NXP Semiconductors PCT2075 I2C-bus Fm+ digital temperature sensor and thermal watchdog The device temperature sensor powers up to measure temperature every 100 ms, with Tidle = 00001 by default. For the PCT2075 with 11-bit accuracy, the ADC conversion is about 28 ms. As a result, the PCT2075 will be idle for (100 ms 28 ms) = 72 ms between two temperature measurements. 7.5 OS output and polarity The OS output is an open-drain output and its state represents results of the device watchdog operation as described in Section 7.1. In order to observe this output state, an external pull-up resistor is needed. The resistor should be as large as possible, up to 1.5 k , to minimize the Temp reading error due to internal heating by the high OS sinking current. The OS output active state can be selected as HIGH or LOW by programming bit B2 (OS_POL) of register Conf: setting bit OS_POL to logic 1 selects OS active HIGH and setting bit B2 to logic 0 sets OS active LOW. At power-up, bit OS_POL is equal to logic 0 and the OS active state is LOW. 7.6 OS comparator and interrupt modes As described in Section 7.1, the device OS output responds to the result of the comparison between register Temp data and the programmed limits, in registers Tos and Thyst, in different ways depending on the selected OS mode: OS comparator or OS interrupt. The OS mode is selected by programming bit B1 (OS_COMP_INT) of register Conf: setting bit OS_COMP_INT to logic 1 selects the OS interrupt mode, and setting to logic 0 selects the OS comparator mode. At power-up, bit OS_COMP_INT is equal to logic 0 and the OS comparator is selected. The main difference between the two modes is that in OS comparator mode, the OS output becomes active when Temp has exceeded Tots and reset when Temp has dropped below Thys, reading a register or putting the device into shutdown mode does not change the state of the OS output; while in OS interrupt mode, once it has been activated either by exceeding Tots or dropping below Thys, the OS output will remain active indefinitely until reading a register, then the OS output is reset. Temperature limits Tots and Thys must be selected so that Tots > Thys. Otherwise, the OS output state will be undefined. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |