| поискавой системы для электроныых деталей |
|
RE46C144SW16F датащи(PDF) 5 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
RE46C144SW16F датащи(HTML) 5 Page - Microchip Technology |
|
5 / 26 page ![]() 2009-2012 Microchip Technology Inc. DS22180C-page 5 RE46C144 TABLE 1-1: AC ELECTRICAL CHARACTERISTICS AC Electrical Characteristics: Unless otherwise indicated, all parameters apply at TA = -25°C to +75°C, VDD =9V, VSS = 0V, Component Values from Typical Application; R9 =100 K, R12 =10 M, C5 = 1.5 nF. Parameter Symbol Test Pin Min Typ Max Units Conditions Oscillator Period TPOSC 12 9.4 10.5 11.5 ms No alarm condition LED and STROBE On Time TON1 11, 4 9.4 10.5 11.5 ms Operating LED Period TPLED1 11 39 43 47 s Standby, no alarm TPLED2 11 .6 .67 .74 s Local alarm condition TPLED3 11 9.6 10.75 11.8 s Timer mode, no local alarm TPLED4 11 LED IS NOT ON s Remote alarm only STROBE and IRED Pulse Period TPER1 4, 6 9.6 10.75 11.8 s Standby, no alarm TPER1A 4, 6 2.42 2.7 2.96 s Standby, after one valid smoke sample TPER1B 4, 6 1.21 1.33 1.47 s Standby, after two consecutive valid smoke samples TPER2 4, 6 1.21 1.33 1.47 s In Local Alarm (three consecu- tive valid smoke samples) TPER3 4, 6 9.7 10.5 11.8 s In Remote Alarm TPER4 4, 6 300 336 370 ms Push-button Test TPER5 4, 6 39 47 s Chamber Test or Low-battery Test, no alarms IRED On Time TON2 6 94 104 115 µs Operating Horn On Time THON1 8, 9 227 252 277 ms Operating, alarm condition, Note 1 THON2 8, 9 9.5 10.5 11.5 ms Low Battery or Failed Chamber Test, no alarm Horn Off Time THOF1 8, 9 76 84 92 ms Operating, Alarm Condition, Note 1 THOF3 8, 9 39 43 47 s Low Battery or Failed Chamber Test, no alarm IO Charge Dump Duration TIODMP 7 .91 1.46 s At conclusion of local alarm or test IO Delay TIODLY1 7 0 s From start of local alarm to IO Active IO Filter TIOFILT 7 600 ms IO pulse-width ensured to be filtered. IO as input, no local alarm Remote Alarm Delay TIODLY2 7 .75 1.65 s No local alarm, from IO Active to Horn Active Timer Period TTPER 7 8.5 10 Min No alarm condition, Note 2 Note 1: See timing diagram for Horn Temporal Pattern 2: During the Timer mode, the LED period is 10.5 seconds. The LED period will return to 43 seconds at the conclusion of the Timer mode. 3: TPOSC and TON2 are 100% production tested. All other timing is guaranteed by functional testing. 4: Typical values are for design information and are not ensured. 5: Limits over the specified temperature range are not production tested and are based on characterization data. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |