| поискавой системы для электроныых деталей |
|
LTC6907 датащи(PDF) 12 Page - Linear Technology |
|
|
|||||||||||||||||||||||||||||
LTC6907 датащи(HTML) 12 Page - Linear Technology |
|
12 / 28 page ![]() LTC6995-1/LTC6995-2 12 699512f For more information www.linear.com/6995 Changing DIVCODE After Start-Up Following start-up, the A/D converter will continue moni- toring VDIV for changes. The LTC6995 will respond to DIVCODE changes in less than one cycle. tDIVCODE < 500 • tMASTER < tOUT The output may have an inaccurate pulse width during the frequency transition. But the transition will be glitch-free and no high or low pulse can be shorter than the mas- ter clock period. A digital filter is used to guarantee the DIVCODEhassettledtoanewvaluebeforemakingchanges to the output. Start-Up Time When power is first applied, the power-on reset (POR) circuit will initiate the start-up time, tSTART. A supply voltage of typically 1.4V (1.2V to 1.5V over temperature) initiates the start-up sequence. The OUT pin is held low during this time. The typical value for tSTART ranges from 0.5msto8msdependingonthemasteroscillatorfrequency (independent of NDIV): tSTART(TYP) = 500 • tMASTER During start-up, the DIV pin A/D converter must deter- mine the correct DIVCODE before the output is enabled. The start-up time may increase if the supply or DIV pin voltages are not stable. For this reason, it is recommended to minimize the capacitance on the DIV pin so it will prop- erly track V+. Less than 100pF will not affect performance. Start-Up Behavior Whenfirstpoweredup,theoutputisheldlow.Ifthepolarity is set for non-inversion (POL = 0) and the output is enabled at the end of the start-up time, OUT will begin oscillating. If the output is being reset (RST = 1 for LTC6995-1 and RST = 0 for LTC6995-2) at the end of the start-up time, it will remain low due to the POL bit = 0. When reset is released the oscillator starts and the output remains low for precisely one half cycle of the programmed period. In inverted operation (POL = 1), the start-up sequence is similar. However, the LTC6995 does not know the correct DIVCODE setting when first powered up, so the output defaults low. At the end of tSTART, the value of DIVCODE is recognizedandOUTgoeshigh(inactive)becausePOL = 1. If the output is being reset (RST = 1 for LTC6995-1 and RST = 0 for LTC6995-2) at the end of the start-up time, it will remain high due to the POL bit = 1. When reset is released the oscillator starts and the output remains high for precisely one half cycle of the programmed period. Figures7to10detailthepossiblestart-upsequences. DIV 200mV/DIV OUT 1V/DIV 10ms/DIV 699512 F05 V+ = 3.3V RSET = 200k V+ 1V/DIV OUT 1V/DIV 250µs/DIV 699512 F06 V+ = 2.5V DIVCODE = 15 RSET = 50k 500µs Figure 5. DIVCODE Change from 1 to 0 Figure 6. Typical Start-Up LTC6995-1 with RST = 0V operaTion |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |