13 / 22 page ![]() ADM9240 –13– REV. 0 To accommodate fans of different speed and/or different num- bers of output pulses per revolution, a prescaler (divisor) of 1, 2, 4 or 8 may be added before the counter. The default value is 2, which gives a count of 153 for a fan running at 4400 rpm pro- ducing two output pulses per revolution. The count is calculated by the equation: Count = (22.5 × 103 × 60) /(rpm × Divisor) For constant speed fans, fan failure is normally considered to have occurred when the speed drops below 70% of nominal, which would correspond to a count of 219. Full scale (255) would be reached if the fan speed fell to 60% of its nominal value. For temperature controlled variable speed fans the situa- tion will be different. Table III shows the relationship between fan speed and time per revolution at 60%, 70% and 100% of nominal rpm for fan speeds of 1100 rpm, 2200 rpm, 4400 rpm and 8800 rpm, and the divisor that would be used for each of these fans, based on two tacho pulses per revolution. Table III. Fan Speeds and Divisors Time per Time per Time per Nominal 70% Rev 60% Rev 60% Rev Divisor rpm (ms) rpm (ms) rpm (ms) 1 8800 6.82 6160 9.74 5280 11.36 2 4400 13.64 3080 19.48 2640 22.73 4 2200 27.27 1540 38.96 1320 45.45 8 1100 54.54 770 77.92 660 90.9 Note that Fan 1 and Fan 2 Divisors are programmed into Bits 4 to 7 of the VID0–VID3/Fan Divisor Register. LIMIT VALUES Fans in general will not overspeed if run from the correct volt- age, so the failure condition of interest is underspeed due to electrical or mechanical failure. For this reason only low speed limits are programmed into the limit registers for the fans. It should be noted that, since fan period rather than speed is being measured, a fan failure interrupt will occur when the measure- ment exceeds the limit value. MONITORING CYCLE TIME The monitoring cycle time depends on the fan speed and num- ber of tacho output pulses per revolution. Two complete periods of the fan tacho output (three rising edges) are required for each fan measurement. Therefore, if the start of a fan measurement just misses a rising edge, the measurement can take almost three tacho periods. In order to read a valid result from the fan value registers, the total monitoring time allowed after starting the monitoring cycle should therefore be three tacho periods of FAN1 plus three tacho periods of FAN2 at the lowest normal fan speed. Although the fan monitoring cycle and the analog input moni- toring cycle are started together, they are not synchronized in any other way. FAN MANUFACTURERS Manufacturers of cooling fans with tachometer outputs are listed below: NMB Tech 9730 Independence Ave. Chatsworth, California 91311 818-341-3355 818-341-8207 Airflow Model Frame Size CFM 2408NL 2.36 in sq. × 0.79 in (60 mm sq. × 20 mm) 9–16 2410ML 2.36 in sq. × 0.98 in (60 mm sq. × 25 mm) 14–25 3108NL 3.15 in sq. × 0.79 in (80 mm sq. × 20 mm) 25–42 3110KL 3.15 in sq. × 0.98 in (80 mm sq. × 25 mm) 25–40 Mechatronis Inc. P.O. Box 613 Preston, WA 98050 800-453-4569 Models—Various sizes available with tach output option. Sanyo Denki/Keymarc Electronics 468 Amapola Ave. Torrance, CA 90501 310-783-5400 Models—109P Series CHASSIS INTRUSION INPUT The Chassis Intrusion (CI) input is an active high input/open- drain output intended for detection and signalling of unautho- rized tampering with the system. An external circuit powered from the system’s CMOS backup battery is used to detect and latch a chassis intrusion event, whether the system is powered up or not. Once a chassis intrusion has been detected and latched, the CI input will generate an interrupt when the system is pow- ered up. The actual detection of chassis intrusion is performed by an external circuit that will, for example, detect when the cover has been removed. A wide variety of techniques may be used for the detection: – Microswitch that opens or closes when the cover is removed. – Reed switch operated by magnet fixed to the cover. – Hall-effect switch operated by magnet fixed to the cover. – Phototransistor that detects light when cover is removed. The chassis intrusion interrupt will remain asserted until the external detection circuit is reset. This can be achieved by set- ting Bit 6 of the Configuration Register, or Bit 7 of the Chassis Intrusion Clear Register to one, which will cause the CI pin to be pulled low for at least 20 ms. These register bits are self-clearing. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |