Back Button AD28msp01KST Datasheet HTML 4Page - Analog Devices AD28msp01KST Datasheet HTML 5Page - Analog Devices AD28msp01KST Datasheet HTML 6Page - Analog Devices AD28msp01KST Datasheet HTML 7Page - Analog Devices AD28msp01KST Datasheet HTML 8Page - Analog Devices AD28msp01KST Datasheet HTML 9Page - Analog Devices AD28msp01KST Datasheet HTML 10Page - Analog Devices AD28msp01KST Datasheet HTML 11Page - Analog Devices AD28msp01KST Datasheet HTML 12Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 8 / 28 page
background image
AD28msp01
REV. A
–8–
If any low-pass filter is bypassed, the resampling interpolation filter should be disabled (in Control Register 0.)
Control Register 2
address = 0x02
This register is used to:
• Select the frequency of the Receive baud clock (RBAUD)
• Select the frequency of the Receive bit clock (RBIT)
BI3-0
Receive bit rate clock selection
0000
=
9600 (default)
0001
=
8000
0010
=
7200
0011
=
4800
0100
=
2400
0101
=
1200
0110
=
600
0111
=
19200
1000
=
14400
1001
=
12000
1010
=
19200 with SA87 in
control register 1 set
(not scaled by 8/7)
0
0
0000
000
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
BA2-0
Receive baud rate clock selection
000
=
2400 (default)
001
=
1600
010
=
1200
011
=
600
100
=
Reserved
101
=
Reserved
110
=
Reserved
111
=
Reserved
Control Register 3
address = 0x03
This register is used to:
• Select the frequency of the Transmit baud clock (TBAUD)
• Select the frequency of the Transmit bit clock (TBIT)
BI3-0
Transmit bit rate clock selection
0000
=
9600 (default)
0001
=
8000
0010
=
7200
0011
=
4800
0100
=
2400
0101
=
1200
0110
=
600
0111
=
19200
1000
=
14400
1001
=
12000
1010
=
19200 with SA87 in
control register 1 set
(not scaled by 8/7)
0
0
0000
000
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
BA2-0
Transmit baud rate clock
selection
000
=
2400 (default)
001
=
1600
010
=
1200
011
=
600
100
=
Reserved
101
=
Reserved
110
=
Reserved
111
=
Reserved



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com