| поискавой системы для электроныых деталей |
|
BL0921 датащи(PDF) 10 Page - SHANGHAI BELLING CO., LTD. |
|
|
|||||||||||||||||||||||||||||
BL0921 датащи(HTML) 10 Page - SHANGHAI BELLING CO., LTD. |
|
10 / 13 page ![]() BL0921 BL0921 BL0921 BL0921 http://www.belling.com.cn - 10 - 3/15/2007 Total 13 Pages Single Phase Energy Meter IC Single Phase Energy Meter IC Single Phase Energy Meter IC Single Phase Energy Meter IC with Integrated Oscillator with Integrated Oscillator with Integrated Oscillator with Integrated Oscillator V1A V1N + - CF RF CT ±660mV AGND V1B + - CF RF CT Rb Rb GAIN ±660mV GAIN Phase Neutral IP IN V1A V1N + - AGND Phase Neutral V1B + - CF RF CT Rb ±660mV GAIN IP IN AGND CF Ra Rb Rv AGND ±660mV Ra >> RF Rb+Rv=RF Figure 7. Typical Connections for Current Channels Fault Detection The BL0921 incorporates a novel fault detection scheme that warns of fault conditions and allows the BL0921 to continue accurate billing during a fault event. The BL0921 does this by continuously monitoring both the phase and neutral (return) currents. A fault is indicated when these currents differ by more than 12.5%. However, even during a fault, the output pulse rate on F1 and F2 is generated using the larger of the two currents. Because the BL0921 looks for a difference between the signals on V1A and V1B, it is important that both current transducers are closely matched. On power-up the output pulse rate of the BL0921 is proportional to the product of the signals on Channel V1A and Voltage Channel. If there is a difference of greater than 12.5% between V1A and V1B on power-up, the fault indicator (FAULT) will go active after about one second. In addition, if V1B is greater than V1A the BL0921 will select V1B as the input. The fault detection is automatically disabled when the voltage signal on Channel 1 is less than 0.5% of the full-scale input range. This will eliminate false detection of a fault due to noise at light loads. If V1A is the active current input (i.e., is being used for billing), and the signal on V1B (inactive input) falls by more than 12.5% of V1A, the fault indicator will go active. Both analog inputs are filtered and averaged to prevent false triggering of this logic output. As a consequence of the filtering, there is a time delay of approximately one second on the logic output FAULT after the fault event. The FAULT logic output is independent of any activity on outputs F1 or F2. Figure 8 illustrates one condition under which FAULT becomes active. Since V1A is the active input and it is still greater than V1B, billing is maintained on VIA, i.e., no swap to the V1B input will occur. V1A remains the active input. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |