| поискавой системы для электроныых деталей |
|
SN55LBC976 датащи(PDF) 5 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
SN55LBC976 датащи(HTML) 5 Page - Texas Instruments |
|
5 / 25 page ![]() SN55LBC976 9-CHANNEL DIFFERENTIAL TRANSCEIVER SGLS091A – JUNE 1995 – REVISED JANUARY 1997 5 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 receiver electrical characteristics over recommended ranges of operating conditions (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP† MAX UNIT VOH High-level output voltage VID = 200 mV, See Figure 3 IOH = – 8 mA, 2.5 V VOL Low-level output voltage VID = – 200 mV, See Figure 3 IOL = 8 mA, 0.8 V ‡ IOH = – 8 mA, See Figure 3 0.2 VIT + Positive-going input threshold voltage‡ IOH = – 8 mA, See Figure 3 TA = – 55°C, 0.5 V VIT – Negative-going input threshold voltage IOL = 8 mA, See Figure 3 – 0.2 V Vhys Receiver input hysteresis ( VIT + – VIT – ) 45 mV VI = 12 V, Other input at 0 V, VCC = 5 V, See Figure 3 0.7 1.5 mA II Receiver input current B+ and B VI = 12 V, Other input at 0 V, VCC = 0 V, See Figure 3 0.8 1.5 mA II Receiver input current B+ and B – VI = – 7 V, Other input at 0 V, VCC = 5 V, See Figure 3 – 0.5 –1 mA VI = – 7 V, Other input at 0 V, VCC = 0 V, See Figure 3 – 0.4 –1 mA IOZ High-impedance-state output current See Figure 3 VO = GND – 200 µA IOZ High-im edance-state out ut current See Figure 3 VO = VCC 50 µA † All typical values are at VCC = 5 V, TA = 25°C. ‡ This parameter is not tested to meet RS-485 or SCSI standards at –55 °C. driver switching characteristics over recommended operating conditions (unless otherwise noted) (see Figure 4) PARAMETER TEST CONDITIONS MIN TYP† MAX UNIT tdD Differential delay time, high-to-low-level output (tdDH) or 4 30 ns tdD y, g ( dDH) low-to-high-level output (tdDL ) VCC = 5 V, TA = 25°C 9 17 ns t k(li ) Skew limit, the maximum difference in propagation delay times 12 ns tsk(lim) ,g y between any two drivers on any two devices VCC = 5 V, See Note 2 8 ns tsk(p) Pulse skew ( | tdDL – tdDH |) 6 ns tt Transition time (tr or tf) 10 ns † All typical values are at VCC = 5 V, TA = 25°C. NOTE 2: This specification applies to any 5 °C band within the operating temperature range. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |