| поискавой системы для электроныых деталей |
|
TLC5903PZP датащи(PDF) 14 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TLC5903PZP датащи(HTML) 14 Page - Texas Instruments |
|
14 / 23 page ![]() TLC5903 LED DRIVER SLLS383 – DECEMBER 1999 14 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 PRINCIPLES OF OPERATION frequency division ratio setting for GSCLK(clock for gray scale) – panel brightness adjustment (continued) CODE FREQUENCY DIVISION RATIO RELATIVE BRIGHTNESS RATIO (%) MSB 000 LSB† 1/1 12.5 001 1/2 25.0 010 1/3 37.5 011 1/4 50.0 100 1/5 62.5 101 1/6 75.0 110 1/7 87.5 111 1/8 100 † BC_ENA is low. constant output current operation The constant current output turns on (sink constant current) if all the gray scale data latched into the gray scale latch is not zero on the falling edge of GCLK after the next rising edge of GCLK when BLANK goes from high to low. After that, the number of the falling edge is counted by the 8-bit gray scale counter. Output counted that corresponds to the gray scale data is turned off (stop to sink constant current). If the shift register for gray scale is updated during LATCH high, data on the gray scale data latch is also updated, affecting the number of gray scale constant current output. Accordingly, during the on state of constant current output, LATCH is kept to low and the gray scale data latch is held. When unconnected constant current output terminals exist, the operation is complete after writing zero (data for LED turn off) to the corresponding gray scale data latch. If this action is not completed, the supply current (I(PVCC)) in the constant current driver portion increases. protection This device incorporates WDT and TSD functions. In the WDT or TSD functions, the current output is stopped (Logic portion is still operating). By monitoring the DOWN terminal, these failures are detected immediately. Since DOWN output is configured as an open collector, outputs of multiple ICs are brought together. WDT When the scan signal is stopped during a fixed period in the dynamic scanning operation, the constant current output is turned off, preventing the LED from burning damage. The time detected can be set using the external capacitor(C1). The typical value is approximately 3 ms without a capacitor, 33 ms with a 1000 pF capacitor, and 300 ms with a 0.01 µF capacitor. Once the scan signal is applied again, the abnormal status is released and normal operation is resumed. During static operation, the WDT function is disabled, connecting WD_CAP to GND. The scan signal should be applied to the WDT terminal even though the WDT function is not used. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |