| поискавой системы для электроныых деталей |
|
LTC2865 датащи(PDF) 14 Page - Linear Technology |
|
|
|||||||||||||||||||||||||||||
LTC2865 датащи(HTML) 14 Page - Linear Technology |
|
14 / 24 page ![]() LTM2881 14 2881fe APPLICATIONS INFORMATION Switchable Termination Proper cable termination is very important for signal fi- delity. If the cable is not terminated with its characteristic impedance, reflections will distort the signal waveforms. The integrated switchable termination resistor provides logic control of the line termination for optimal perfor- mance when configuring transceiver networks. When the TE pin is high, the termination resistor is enabled and the differential resistance from A to B is 120Ω. Figure 11 shows the I/V characteristics between pins A and B with the termination resistor enabled and disabled. The resistance is maintained over the entire RS485 common mode range of –7V to 12V as shown in Figure 12. The integrated termination resistor has a high frequency re- sponse which does not limit performance at the maximum specified data rate. Figure 13 shows the magnitude and Figure 13. Termination Magnitude and Phase vs Frequency Figure 12. Termination Resistance vs Common Mode Voltage Figure 11. Curve Trace Between A and B with Termination Enabled and Disabled 2881 F11 COMMON MODE VOLTAGE (V) 130 128 126 124 122 120 118 116 114 112 110 2881 G11 15 10 5 –5 0 –10 FREQUENCY (MHz) 150 140 130 120 110 100 10 0 –10 –20 –30 –40 2881 F13 10 1 0.1 PHASE MAGNITUDE Figure 14. Supply Current vs Data Rate DATA RATE (Mbps) 2881 F14 10 1 0.1 250 230 210 190 170 150 130 110 90 70 50 LTM2881-3 R=54 CL=1000p R=54 CL=100p R=54 CL=0 LTM2881-5 R=54 CL=1000p R=54 CL=100p R=54 CL=0 phase of the termination impedance versus frequency. The termination resistor cannot be enabled by TE if the device is unpowered, ON is low or the LTM2881 is in thermal shutdown. Supply Current The static supply current is dominated by power delivered to the termination resistance. Power supply current increases with data rate due to capacitive loading. Figure 14 shows supply current versus data rate for three different loads for the circuit configuration of Figure 4. Supply current increases with additional external applications drawing current from VCC2. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |