| поискавой системы для электроныых деталей |
|
ADM1075 датащи(PDF) 21 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADM1075 датащи(HTML) 21 Page - Analog Devices |
|
21 / 52 page ![]() Data Sheet ADM1075 Rev. A | Page 21 of 52 RSENSE Q1 SENSE– VEE GATE VIN SENSE+ ADM1075 RDROP = 15Ω –48V RTN –48V 11V VEE 1µF Rb1 = 100kΩ Rb2 = 640Ω Ib = 6µA TO 33µA 10.3V (5.5mA TO 10mA) CIN CLOAD 18V TO 75V Figure 43. Wide Input Supply Range CURRENT SENSE INPUTS The load current is monitored by measuring the voltage drop across an external sense resistor, RSENSE. An internal current sense amplifier provides a gain of 25 or 50 (depending on the model) to the voltage drop detected across RSENSE. The result is compared to an internal reference and detects when an overcurrent condition occurs. RSENSE Q1 SENSE– VEE GATE VIN SENSE+ ADM1075 OVER- CURRENT 1V REF ×25/50 + – – Figure 44. Hot-Swap Current Sense Amplifier The SENSE± inputs can be connected to multiple parallel sense resistors, which can affect the voltage drop detected by the ADM1075. The current flowing through the sense resistors creates an offset, resulting in reduced accuracy. To achieve better accuracy, averaging resistors should be used to sum the sense nodes of each sense resistor, as shown in Figure 45. The typical value for the averaging resistors is 10 Ω. The value of the averaging resistors is chosen to be much greater than the trace resistance between the sense resistor terminals and the inputs to the ADM1075. This greatly reduces the effects of differences in the trace resistances. Q1 SENSE– VEE GATE VIN SENSE+ ADM1075 BIAS CURRENT Figure 45. Connection of Multiple Sense Resistors to SENSE± Pins CURRENT LIMIT REFERENCE The current limit reference voltage determines the load current level to which the ADM1075 limits the current during an overcurrent event. This is the reference voltage to which the gained up current sense voltage is compared to determine if the limit is reached. This current limit voltage, shown in Figure 46, is then converted to a gate current to regulate the GATE pin. m LIM CURR GATE g V I × = _ where gm, the gate transconductance, = 660 μS. An internal current limit reference selector block continuously compares the ISET, soft start, and foldback (derived from PLIM) voltages, determines which is the lowest at any given time, and uses it as the current limit reference. This ensures that the programmed current limit, ISET, is used in normal operation and the soft start and foldback features reduce the current limit when required. The foldback and soft start voltages change during different stages of operation and are clamped to a lower level of 100 mV (typical) to prevent zero current flow due to the current limit being too low. GATE SENSE+ ADM1075 VEE SENSE– SS CURRENT LIMIT VOLTAGE FLB ( = 0.1/PLIM) ISET TIMEOUT CURRENT LIMIT CONTROL REF SELECT 1.0V CURRENT LIMIT VCAP 10µA GATE DRIVE LOGIC PLIM – ×25/50 + + – Figure 46. Current Limit Reference Selection |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |