23 / 32 page ![]() LTC4270/LTC4271 23 42701f APPLICATIONS INFORMATION Table 5. Example Current Limit Settings ILIM (mA) INTERNAL REGISTER SETTING (hex) RSENSE = 0.5Ω RSENSE = 0.25Ω 53 88 106 08 88 159 89 213 80 08 266 8A 319 09 89 372 8B 425 00 80 478 8E 531 92 8A 584 CB 638 10 90 744 D2 9A 850 40 C0 956 4A CA 1063 50 D0 1169 5A DA 1275 60 E0 1488 52 49 1700 40 1913 4A 2125 50 2338 5A 2550 60 2975 52 ILIM Foldback The LTC4270/LTC4271 features a two-stage foldback circuit that reduces the port current if the port voltage falls below the normal operating voltage. This keeps MOSFET power dissipation at safe levels for typical 802.3af MOSFETs, even at extended 802.3at power levels. Current limit and foldback behavior are programmable on a per-port basis. Table 5 gives examples of recommended ILIM register settings. The LTC4270/LTC4271 will support current levels well beyond the maximum values in the 802.3at specification. The shaded areas in Table 5 indicate settings that may require a larger external MOSFET, additional heat sinking, or setting tLIM Enable. MOSFET Fault Detection LTC4270/LTC4271 PSE ports are designed to tolerate significant levels of abuse, but in extreme cases it is pos- sible for the external MOSFET to be damaged. A failed MOSFET may short source to drain, which will make the port appear to be on when it should be off; this condition may also cause the sense resistor to fuse open, turning off the port but causing the LTC4270 SENSE pin to rise to an abnormally high voltage. A failed MOSFET may also short from gate to drain, causing the LTC4270 GATE pin to rise to an abnormally high voltage. The LTC4270 OUT, SENSE and GATE pins are designed to tolerate up to 80V faults without damage. If the LTC4270/LTC4271 sees any of these conditions for more than 180μs, it disables all port functionality, reduces the gate drive pull-down current for the port and reports a FET Bad fault. This is typically a permanent fault, but the host can attempt to recover by resetting the port, or by resetting the entire chip if a port reset fails to clear the fault. If the MOSFET is in fact bad, the fault will quickly return, and the port will disable itself again. The remaining ports of the LTC4270/LTC4271 are unaffected. An open or missing MOSFET will not trigger a FET Bad fault, but will cause a tSTART fault if the LTC4270/LTC4271 attempts to turn on the port. Port Current Readback The LTC4270/LTC4271 measures the current at each port with an internal A/D converter. Port data is only valid when the port power is on and reads zero at all other times. The converter has two modes: • 100ms mode: Samples are taken continuously and the measured value is updated every 100ms • 1s mode: Samples are taken continuously; a moving 1 second average is updated every 100ms |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |