| поискавой системы для электроныых деталей |
|
MIC3003 датащи(PDF) 53 Page - Micrel Semiconductor |
|
|
|||||||||||||||||||||||||||||
MIC3003 датащи(HTML) 53 Page - Micrel Semiconductor |
|
53 / 75 page ![]() Micrel, Inc. MIC3003 November 2009 53 M9999-111209-C hbwhelp@micrel.com or (408) 955-1690 Power-On Hours (POHh and POHl) D[7] read/write D[6] read/write D[5] read/write D[4] read/write D[3] read/write D[2] read/write D[1] read/write D[0] read/write Default value of both bytes when the MIC3003 is shipped from the factory 0000 0000b = 00h Serial address A6h Bytes addresses MS byte (POHh): 251 = FBh LS byte (POHl): 252 = FCh The lower seven bits of POHh contain the most significant bits of the 15-bit power-on hours measurement. The value in POHh should be combined with the eight-bit power-on hours low byte, POHl, to yield the complete result. The most significant bit of POHh, POHFLT, is an error flag. If POHFLT is set, the power-on hour meter data has been corrupted and should be ignored. It is recommended that a two-byte sequential (block) SMBus read operation be performed on POHh and POHl to insure coherency between the two registers. This register is non-volatile and will be maintained through power and reset cycles, including unanticipated power failures. POHh Bit(s) Function Operation D[7] Power-on hours fault flag, POHFLT 1 = fault: the power-on hours value is corrupted and cannot be relied upon 0 = no fault: the power-on hours value is correct D[6:0] Power-on hours, most significant seven bits Data Ready Flags (DATARDY) D[7] TRDY read/write D[6] VRDY read/write D[5] IRDY read/write D[4] TXRDY read/write D[3] RXDY read/write D[2] reserved D[1] reserved D[0] reserved Default value 0000 0000b = 00h Serial address A6h Byte address 253 = FDh When the A/D conversion for a given parameter is completed and the results available to the host, the appropriate data ready flag will be set. The flag will be cleared when the host reads the corresponding result register. Bit(s) Function Operation D[7] TRDY Temperature data ready flag 0 = Result register contains old data; 1 = new data ready D[6] VRDY Voltage data ready flag 0 = Result register contains old data; 1 = new data ready D[5] IRDY Bias current data ready flag 0 = Result register contains old data; 1 = new data ready D[4] TXRDY Transmit power data ready flag 0 = Result register contains old data; 1 = new data ready D[3] RXRDY Receive power data ready flag 0 = Result register contains old data; 1 = new data ready D[2:0] Reserved Reserved |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |