11 / 19 page ![]() Data Sheet TLE 6220 GP V2.1 Page 2007-05-03 11 Diagnostics FAULT - Fault pin. There is a general fault pin (open drain) which shows a high to low transi- tion as soon as an error occurs for any one of the four channels. This fault indication can be used to generate a µC interrupt. Therefore a ‘diagnosis’ interrupt routine need only be called after this fault indication. This saves processor time compared to a cyclic reading of the SO in- formation. As soon as a fault occurs, the fault information is latched into the diagnosis register. A new er- ror will over-write the old error report. Serial data out pin (SO) is in a high impedance state when CS is high. If CS receives a LOW signal, all diagnosis bits can be shifted out serially. The rising edge of CS will reset all error registers. Full Diagnosis For full diagnosis there are two diagnostic bits per channel configured as shown in Figure 1. Normal function: The bit combination HH indicates that there is no fault condition, i.e. normal function. Overload, Short Circuit to Battery (SCB) or Overtemperature:HL is set when the current limitation gets active, i.e. there is a overload, short to supply or overtemperature condition. Open load: An open load condition is detected when the drain voltage decreases below 3 V (typ.). LH bit combination is set. Short Circuit to GND: If a drain to ground short circuit exists and the drain to ground current exceeds 100 µA, short to ground is detected and the LL bit combination is set. A definite distinction between open load and short to ground is guaranteed by design. The standard way of obtaining diagnostic information is as follows: Clock in serial information into SI pin and wait approximately 150 µs to allow the outputs to set- tle. Clock in the identical serial information once again - during this process the data coming out at SO contains the bit combinations representing the diagnosis conditions as described in Fig- ure 1. Diagnostic Serial OUT (SO) HH Normal function HL Overload, Shorted Load or Overtemperature LH Open Load LL Shorted to Ground Ch.4 Ch.3 Ch.2 Ch.1 7 6 5 4 3 2 1 0 Figure 1: Two bits per channel diagnostic feedback |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |