TLE7240SL датащи(PDF) 21 Page - Infineon Technologies AG

номер детали TLE7240SL
подробное описание детали  8 Channel Protected Low-Side Relay Switch
PDF  28 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
производитель  INFINEON [Infineon Technologies AG]
домашняя страница  http://www.infineon.com
Logo INFINEON - Infineon Technologies AG

TLE7240SL датащи(HTML) 21 Page - Infineon Technologies AG

Back Button TLE7240SL Datasheet HTML 17Page - Infineon Technologies AG TLE7240SL Datasheet HTML 18Page - Infineon Technologies AG TLE7240SL Datasheet HTML 19Page - Infineon Technologies AG TLE7240SL Datasheet HTML 20Page - Infineon Technologies AG TLE7240SL Datasheet HTML 21Page - Infineon Technologies AG TLE7240SL Datasheet HTML 22Page - Infineon Technologies AG TLE7240SL Datasheet HTML 23Page - Infineon Technologies AG TLE7240SL Datasheet HTML 24Page - Infineon Technologies AG TLE7240SL Datasheet HTML 25Page - Infineon Technologies AG Next Button
Zoom Inzoom in Zoom Outzoom out
 21 / 28 page
background image
Data Sheet
21
Rev. 1.1, 2009-04-15
SPI Driver for Enhanced Relay Control
SPIDER - TLE 7240SL
Serial Peripheral Interface (SPI)
Figure 11
Data Transfer in Daisy Chain Configuration
8.3
SPI Protocol
The SPI protocol of the SPIDER - TLE 7240SL provides two registers. The input register and the diagnosis
register. The diagnosis register contains four pairs of diagnosis flags, the input register contains the input
multiplexer configuration. After power-on reset, all register bits are set to 1 and the device is in idle mode.
If all channels are in Standby Mode, the device is in power down status with minimum current consumption (sleep
mode).
SI
Default: FFFFH
15
14
13
12
11
10
9
876
543
210
IN8
IN7
IN6
IN5
IN4
IN3
IN2
IN1
Field
Bits
Type
Description
INn
(n = 8 - 1)
15:14,
13:12,
11:10,
9:8,
7:6,
5:4,
3:2,
1:0
W
Input Register Channel n
00B Stand-by Mode:
Fast channel switched off.
Diagnosis flags are cleared.
Diagnosis current is disabled.
01B Input Mode:
Channel is switched according to signal at input pin.
Diagnosis current is enabled in OFF-state.
10B ON Mode:
Channel is switched on.
11B OFF Mode:
Channel is switched off.
Diagnosis current is enabled.
MI
MO
MCS
MCLK
SI device 3
SI device 2
SI device 1
SO device 3
SO device 2
SO device 1
time
SPI_DasyChain2.emf



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com