| поискавой системы для электроныых деталей |
|
360 датащи(PDF) 16 Page - Intel Corporation |
|
|
|||||||||||||||||||||||||||||
360 датащи(HTML) 16 Page - Intel Corporation |
|
16 / 95 page ![]() Electrical Specifications 16 Datasheet 2.4 Reserved, Unused, and TESTHI Signals All RESERVED lands must remain unconnected. Connection of these lands to VCC, VSS, VTT, or to any other signal (including each other) can result in component malfunction or incompatibility with future processors. See Chapter 4 for a land listing of the processor and the location of all RESERVED lands. In a system level design, on-die termination has been included by the processor to allow signals to be terminated within the processor silicon. Most unused GTL+ inputs should be left as no connects as GTL+ termination is provided on the processor silicon. However, see Table 7 for details on GTL+ signals that do not include on-die termination. Unused active high inputs, should be connected through a resistor to ground (VSS). Unused outputs can be left unconnected, however this may interfere with some TAP functions, complicate debug probing, and prevent boundary scan testing. A resistor must be used when tying bidirectional signals to power or ground. When tying any signal to power or ground, a resistor will also allow for system testability. Resistor values should be within ± 20% of the impedance of the motherboard trace for front side bus signals. For unused GTL+ input or I/O signals, use pull-up resistors of the same value as the on-die termination resistors (RTT). For details see Table 16. TAP, GTL+ Asynchronous inputs, and GTL+ Asynchronous outputs do not include on-die termination. Inputs and utilized outputs must be terminated on the motherboard. Unused outputs may be terminated on the motherboard or left unconnected. Note that leaving unused outputs unterminated may interfere with some TAP functions, complicate debug probing, and prevent boundary scan testing. All TESTHI[13:0] lands should be individually connected to VTT via a pull-up resistor that matches the nominal trace impedance. The TESTHI signals may use individual pull-up resistors or be grouped together as detailed below. A matched resistor must be used for each group: •TESTHI[1:0] •TESTHI[7:2] • TESTHI8 – cannot be grouped with other TESTHI signals • TESTHI9 – cannot be grouped with other TESTHI signals • TESTHI10 – cannot be grouped with other TESTHI signals • TESTHI11 – cannot be grouped with other TESTHI signals • TESTHI12 – cannot be grouped with other TESTHI signals • TESTHI13 – cannot be grouped with other TESTHI signals However, use of boundary scan test will not be functional if these lands are connected together. For optimum noise margin, all pull-up resistor values used for TESTHI[13:0] lands should have a resistance value within ± 20% of the impedance of the board transmission line traces. For example, if the nominal trace impedance is 50 Ω, then a value between 40 Ω and 60 Ω should be used. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |