21 / 28 page ![]() AD5749 Rev. 0 | Page 21 of 28 Readback Operation Readback mode is activated by selecting the correct device address (A2, A1, A0) and then setting the R/W bit to 1. By default, the SDO pin is disabled. After having addressed the AD5749 for a read operation, setting R/W to 1 enables the SDO pin and SDO data is clocked out on the 5th rising edge of SCLK. After the data has been clocked out on SDO, a rising edge on SYNC disables (tristate) the SDO pin again. Status register data (see ) and control register data are both available during the same read cycle. Table 9 The status bits comprise four read-only bits. They are used to notify the user of specific fault conditions that occur, such as an open circuit on the output, overtemperature error or an interface error. If any of these fault conditions occur, a hardware FAULT is also asserted low, which can be used as a hardware interrupt to the controller. See the Detailed Description of Features section for a full explanation of fault conditions. HARDWARE CONTROL Hardware control is enabled by connecting the HW SELECT pin to DVCC. In this mode, the R3, R2, R1, and R0 pins, in conjunction with the RSET pin, are used to configure the output range, as per Table 8. In hardware mode, there is no status register. The fault conditions (open circuit, and overtemperature) are available on Pin IFAULT and Pin TEMP. If any one of these fault conditions is set, a low is asserted on the specific fault pin. IFAULT and TEMP are open- drain outputs and, therefore, can be connected together to allow the user to generate one interrupt to the system controller to commun- icate a fault. If hardwired in this way, it is not possible to isolate which fault occurred in the system. TRANSFER FUNCTION The AD5749 consists of an internal signal conditioning block that maps the analog input voltage to a programmed output range. The available analog input range is 0 V to 4.096 V. For all ranges, the AD5749 implements a straight linear mapping function, where 0 V maps to the lower end of the selected range and 4.096 V maps to the upper end of the selected range. Table 9. Input Shift Register Contents for a Read Operation—Status Register MSB LSB D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 A2 A1 A0 1 0 R3 R2 R1 R0 CLRSEL OUTEN RSET PEC Error OVER TEMP IOUT Fault Unused Table 10. Status Bit Options Bit Description PEC Error This bit is set if there is an interface error detected by CRC-8 error checking. See the Detailed Description of Features section. OVER TEMP This bit is set if the AD5749 core temperature exceeds approximately 150°C. IOUT Fault This bit is set if there is an open circuit on the IOUT pin. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |