| поискавой системы для электроныых деталей |
|
TMP112 датащи(PDF) 12 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
TMP112 датащи(HTML) 12 Page - Texas Instruments |
|
12 / 25 page ![]() SLAVE MODE OPERATIONS Slave Receiver Mode: GENERAL CALL HIGH-SPEED (Hs) MODE Slave Transmitter Mode: SMBus ALERT FUNCTION TIMEOUT FUNCTION TMP112 SBOS473B – MARCH 2009 – REVISED JUNE 2009 ......................................................................................................................................................... www.ti.com reads from the same register are desired, it is not For POL = '0', this bit is low if the temperature is necessary to continually send the Pointer Register greater than or equal to THIGH; this bit is high if the bytes, because the TMP112 remembers the Pointer temperature is less than TLOW. The polarity of this bit Register value until it is changed by the next write is inverted if POL = '1'. Refer to Figure 18 for details operation. of this sequence. Note that register bytes are sent with the most If multiple devices on the bus respond to the SMBus significant byte first, followed by the least significant Alert command, arbitration during the slave address byte. portion of the SMBus Alert command determines which device clears its ALERT status. The device with the lowest two-wire address wins the arbitration. If the TMP112 wins the arbitration, its ALERT pin The TMP112 can operate as a slave receiver or slave becomes inactive at the completion of the SMBus transmitter. As a slave device, the TMP112 never Alert command. If the TMP112 loses the arbitration, drives the SCL line. its ALERT pin remains active. The first byte transmitted by the master is the slave The TMP112 responds to a two-wire General Call address, with the R/W bit low. The TMP112 then address (0000000) if the eighth bit is '0'. The device acknowledges reception of a valid address. The next acknowledges the General Call address and byte transmitted by the master is the Pointer responds to commands in the second byte. If the Register. The TMP112 then acknowledges reception second byte is 00000110, the TMP112 internal of the Pointer Register byte. The next byte or bytes registers are reset to power-up values. The TMP112 are written to the register addressed by the Pointer does not support the General Address acquire Register. The TMP112 acknowledges reception of command. each data byte. The master can terminate data transfer by generating a START or STOP condition. In order for the two-wire bus to operate at frequencies above 400kHz, the master device must issue an The first byte transmitted by the master is the slave Hs-mode master code (00001xxx) as the first byte address, with the R/W bit high. The slave after a START condition to switch the bus to acknowledges reception of a valid slave address. The high-speed operation. The TMP112 does not next byte is transmitted by the slave and is the most acknowledge this byte, but switches its input filters on significant byte of the register indicated by the Pointer SDA and SCL and its output filters on SDA to operate Register. The master acknowledges reception of the in Hs-mode, allowing transfers at up to 3.4MHz. After data byte. The next byte transmitted by the slave is the Hs-mode master code has been issued, the the least significant byte. The master acknowledges master transmits a two-wire slave address to initiate a reception of the data byte. The master can terminate data transfer operation. The bus continues to operate data transfer by generating a Not-Acknowledge on in Hs-mode until a STOP condition occurs on the bus. reception of any data byte, or generating a START or Upon receiving the STOP condition, the TMP112 STOP condition. switches the input and output filters back to fast-mode operation. The TMP112 supports the SMBus Alert function. When the TMP112 operates in Interrupt mode (TM = The TMP112 resets the serial interface if SCL is held '1'), the ALERT pin may be connected as an SMBus low for 30ms (typ). The TMP112 releases the bus if it Alert signal. When a master senses that an ALERT is pulled low and waits for a START condition. To condition is present on the ALERT line, the master avoid activating the timeout function, it is necessary sends an SMBus Alert command (00011001) to the to maintain a communication speed of at least 1kHz bus. If the ALERT pin is active, the device for SCL operating frequency. acknowledges the SMBus Alert command and responds by returning its slave address on the SDA line. The eighth bit (LSB) of the slave address byte indicates if the ALERT condition was caused by the temperature exceeding THIGH or falling below TLOW. 12 Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated Product Folder Link(s): TMP112 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |