24 / 36 page ![]() CS5530 24 DS742F3 2.5.2 Continuous Conversion Mode When the user transmits the perform continuous conversion command, the converter begins contin- uous conversions using the word rate and polarity selections set in the configuration register. Once the command byte is transmitted, the serial port en- ters data mode where it waits until a conversion is complete. After the conversion is done, SDO falls to logic 0 to act as a flag to indicate that the data is available. Forty SCLKs are then needed to read the conversion. The first 8 SCLKs are used to clear the SDO flag. The last 32 SCLKs are needed to read the conversion result. If ‘00000000’ is provided to SDI during the first 8 SCLKs when the SDO flag is cleared, the converter remains in this conversion mode and continues to convert using the same word rate and polarity information. In continuous con- version mode, not every conversion word needs to be read. The user needs only to read the conversion words required for the application as SDO rises and falls to indicate the availability of new conversion data. Note that if a conversion is not read before the next conversion data becomes available, it will be lost and replaced by the new conversion data. To exit this conversion mode, the user must provide ‘11111111’ to the SDI pin during the first 8 SCLKs after SDO falls. If the user decides to exit, 32 SCLKs are required to clock out the last conversion before the converter returns to command mode. The number of clock cycles a continuous conver- sion takes for each Output Word Setting is listed in Table 2. The first conversion from the part in con- tinuous conversion mode will be longer than the following conversions due to start-up overhead. The ± 8 (FRS = 0) or ± 10 (FRS = 1) clock ambigu- ity is due to internal synchronization between the SCLK input and the oscillator. Note: When changing channels, or after performing calibrations and/or single conversions, the user must ignore the first three (for OWRs less than 3200 Sps, MCLK = 4.9152 MHz) or first five (for OWR ≥ 3200 Sps) conversions in continuous conversion mode, as residual filter coefficients must be flushed from the filter before accurate conversions are performed. Table 1. Conversion Timing for Single Mode (WR3-WR0) Clock Cycles FRS = 0 FRS = 1 0000 171448 ± 8 205738 ± 10 0001 335288 ± 8 402346 ± 10 0010 662968 ± 8 795562 ± 10 0011 1318328 ± 8 1581994 ± 10 0100 2629048 ± 8 3154858 ± 10 1000 7592 ± 8 9110 ± 10 1001 17848 ± 8 21418 ± 10 1010 28088 ± 8 33706 ± 10 1011 48568 ± 8 58282 ± 10 1100 89528 ± 8 107434 ± 10 Table 2. Conversion Timing for Continuous Mode FRS (WR3-WR0) Clock Cycles (First Conversion) Clock Cycles (All Other Conversions) 0 0000 89528 ± 8 40960 0 0001 171448 ± 8 81920 0 0010 335288 ± 8 163840 0 0011 662968 ± 8 327680 0 0100 1318328 ± 8 655360 0 1000 2472 ± 8 1280 0 1001 12728 ± 8 2560 0 1010 17848 ± 8 5120 0 1011 28088 ± 8 10240 0 1100 48568 ± 8 20480 1 0000 107434 ± 10 49152 1 0001 205738 ± 10 98304 1 0010 402346 ± 10 196608 1 0011 795562 ± 10 393216 1 0100 1581994 ± 10 786432 1 1000 2966 ± 10 1536 1 1001 15274 ± 10 3072 1 1010 21418 ± 10 6144 1 1011 33706 ± 10 12288 1 1100 58282 ± 10 24576 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |