| поискавой системы для электроныых деталей |
|
LTC4010CFE датащи(PDF) 21 Page - Linear Technology |
|
|
|||||||||||||||||||||||||||||
LTC4010CFE датащи(HTML) 21 Page - Linear Technology |
|
21 / 24 page ![]() LTC4010 4010fb 1. Input capacitors should be placed as close as possible to switching FET supply and ground connections with the shortest copper traces possible. The switching FETs must be on the same layer of copper as the input capacitors. Vias should not be used to make these connections. 2. Place the LTC4010 close to the switching FET gate terminals, keeping the connecting traces short to produce clean drive signals. This rule also applies to IC supply and ground pins that connect to the switching FET source pins. The IC can be placed on the opposite side of the PCB from the switching FETs. 3. Place the inductor input as close as possible to the drain of the switching FETs. Minimize the surface area of the switch node. Make the trace width the minimum needed to support the programmed charge current. Use no copper fills or pours. Avoid running the con- nection on multiple copper layers in parallel. Minimize capacitance from the switch node to any other trace or plane. 4. Place the charge current sense resistor immediately adjacent to the inductor output, and orient it such that current sense traces to the LTC4010 are not long. These feedback traces need to be run together as a single pair with the smallest spacing possible on any given layer on which they are routed. Locate any filter component on these traces next to the LTC4010, and not at the sense resistor location. 5. Place output capacitors next to the sense resisitor output and ground. applicaTions inForMaTion 6. Output capacitor ground connections must feed into the same copper that connects to the input capacitor ground before tying back into system ground. 7. Connection of switching ground to system ground, or any internal ground plane should be single-point. If the system has an internal system ground plane, a good way to do this is to cluster vias into a single star point to make the connection. 8. RouteanaloggroundasatracetiedbacktotheLTC4010 GND pin before connecting to any other ground. Avoid usingthesystemgroundplane.AusefulCADtechnique is to make analog ground a separate ground net and use a 0Ω resistor to connect analog ground to system ground. 9. A good rule of thumb for via count in a given high current path is to use 0.5A per via. Be consistent when applying this rule. 10. If possible, place all the parts listed above on the same PCB layer. 11. Copper fills or pours are good for all power connec- tions except as noted above in Rule 3. Copper planes on multiple layers can also be used in parallel. This helps with thermal management and lowers trace in- ductance, which further improves EMI performance. 12. For best current programming accuracy, provide a Kelvin connection from RSENSE to SENSE and BAT. See Figure 13 for an example. 13. It is important to minimize parasitic capacitance on the TIMER, SENSE and BAT pins. The traces connecting these pins to their respective resistors should be as short as possible. Figure 12. High Speed Switching Path 4010 F12 VBAT L1 VIN HIGH FREQUENCY CIRCULATING PATH BAT SWITCH NODE CIN SWITCHING GROUND COUT D1 Figure 13. Kelvin Sensing of Charge Current SENSE 4010 F13 DIRECTION OF CHARGING CURRENT RSENSE BAT |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |