AS8520 датащи(PDF) 16 Page - ams AG

номер детали AS8520
подробное описание детали  LIN Transceiver with Voltage Regulator, Attenuator, Relay Drivers, MCU Interface for Automotive Applications
PDF  34 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
производитель  AMSCO [ams AG]
домашняя страница  http://www.ams.com
Logo AMSCO - ams AG

AS8520 датащи(HTML) 16 Page - ams AG

Back Button AS8520 Datasheet HTML 12Page - ams AG AS8520 Datasheet HTML 13Page - ams AG AS8520 Datasheet HTML 14Page - ams AG AS8520 Datasheet HTML 15Page - ams AG AS8520 Datasheet HTML 16Page - ams AG AS8520 Datasheet HTML 17Page - ams AG AS8520 Datasheet HTML 18Page - ams AG AS8520 Datasheet HTML 19Page - ams AG AS8520 Datasheet HTML 20Page - ams AG Next Button
Zoom Inzoom in Zoom Outzoom out
 16 / 34 page
background image
www.austriamicrosystems.com/Lin_CompanionIC/AS8520
Revision 0.01
16 - 34
AS8520
Preliminary Data Sheet - D e t a i l e d D e s c r i p t i o n
Figure 5. Window Watchdog Trigger
7.1.7 Resistive Divider
The resistive divider acts as a battery voltage attenuator. The output of this resistive divider can be connected to an ADC for monitoring the
battery voltage. The division ratio of resistive divider is 21 but can be set also to 481 as a factory programming option. Both divider options can
be disabled in standby mode using the EN signal. Reverse polarity protection of VBAT pin is provided.
7.1.8 HV Low Side Relay Driver Switches
Two NMOS open drain relay driver devices provide over voltage protection. The Driver is disabled if the MCU software hangs up (watchdog reset
or time out WD for LIN TX). The input to the drivers is given through SPI (Low-side driver data register). If over voltage occurs, the Relay driver
turns off irrespective of the input. The driver stays turned off till the voltage returns back to the normal operating range. An optional control bit
available in the Device configuration register, which can be used to switch off the drivers independently to save power. The relay drivers are
disabled using the SPI.
7.1.9 LIN Transceiver
The transceiver provides short circuit limitation, hardware watchdog and over temperature shut down features. The TX watchdog timer is active
when TX is pulled low (active). As soon as the TX watchdog timeout occurs, the LIN bus is released from dominant state to recessive state. The
LIN transceiver has a pull-up resistor (for the slave node; extra resistor externally for the master node) to the VSUP. A diode protection is
available to protect it from back supply from bus line.
The LIN transmitter has the basic functionality of relaying the data from the micro-controller on to the LIN. The data on the LIN needs to have
controlled slew to have reduced EMI. The receiver relays the data from the LIN to the micro-controller. This transmitter has optimized EMC
performance across different loading conditions conforming to the LIN 2.1 standards. The wake-up detects a wake up event on the LIN.
7.2 Operating Modes and States
The AS8520 provides four main operating modes “normal”, “sleep/stand-by” (programmed by OTP), “temporary shutdown” and “thermal
shutdown”. The LIN transceiver can be programmed to operate with lower slew in the normal mode. Refer to Table 14 for a detailed description
on transition for each mode.
7.2.1 Normal Mode
This is the mode after the power-up. In normal mode, LDO, LIN Transceiver, Window Watchdog, Resistive divider and the line drivers are all
turned on. All the blocks are completely functional. LDO is now capable of delivering maximum load current possible as per the device
specifications. The LIN Transceiver is capable of sending the TX data from microcontroller to the LIN bus at a maximum rate of 20Kbps.
Resistive divider is used to attenuate the battery voltage and relay drivers are used to drive the relay. EN signal is set to high and LIN, TX, RX
pins can be driven into dominant (low) or recessive (high) states. If the junction temperature increases more than Totset, a warning flag is set in
the diagnostic register, which can be read through the SPI interface.
Period
Non-Service time (WD_TCL)
Service time (WD_TSV)
Trigger
restart
period
Trigger via
SPI
Last trigger point
Earliest possible
trigger point
(System will not
RESET)
latest possible
trigger point
(System wil not be
RESET)
50 %
100 %
Valid Trigger point
(System will not be
RESET)
Unwanted trigger point
(System will be
RESET)



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com