| поискавой системы для электроныых деталей |
|
AS8500 датащи(PDF) 13 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS8500 датащи(HTML) 13 Page - ams AG |
|
13 / 41 page ![]() AS8500 - Data Sheet austriamicrosystems Revision 1.2, 08-Junel-06 www.austriamicrosystems.com Page 13 of 41 7.2.3 Internal temperature sensor The ASSP contains a high sensitive precision temperature sensor which can be used at any time. The sensor supplies a very linear voltage with temperature. The voltage can be measured using the internal circuitry with gain 6, with free selection of all other parameters defining the sampling rate. The slope of the curve is approx. 75 digits per degC. The calculation of the temperature has to be done in the external µ C acc. to the following simple formula: Tint=( Uint(T)-Uint(23) ) / 75 + 23°C Uint(T) is the measured result and Uint(23) is the reference value at 23°C, which is stored as an 11 bit-word in the ZZR-register. 7.3 Digital part In the digital part the result of the AD-converter is processed, i.e. calibration, active offset cancellation and filtering is done. In addition the communication via the serial SDI interface is handled and all circuit functions (like voltage and current path settings, chopping, dechopping) are controlled. Whenever the power supply line returns from below POR threshold a power-up circuitry is activated which loads the internal calibration registers from the Zener-Zap memory into the working register and starts the chip in a special default mode. 7.3.1 Sampling rate the sampling rate (SR) is defined by the setting of parameters in register CRA or CRB. The oversampling frequency (OSF), the oversampling ratio (OSR), the chopping ratio (MM) and the averaging number (AV). The sampling rate can be calculated acc. to the following formula: SR= OSF/(OSR*MM*AV) For an clock frequency of 8.192 MHz it can vary between 16 000 Hz and 1.95 Hz. In the dual mode (see 7.4 mode 2) the ASSP is switching automatically between the two channels and it needs at least one measurement for each polarity to get a valid measurement. In addition the ASSP needs some time to reprogram the internal registers and switches. Therefore the maximum sampling frequency is limited to 7.5 kHz for the above given clock frequency. The internal averaging is not working in the dual mode, but the sampling frequency can be different for each channel. 7.3.2 Calibration The calibration of the ASSP is done by a test setup as follows: - room temperature calibration of the internal temperature sensor - absolute input-output calibration for all gain settings - TC calibration for the measurement path for gain 24 measurement of internal temperature sensor over oil bath temperature 15000 20000 25000 30000 35000 -50 -25 0 25 50 75 100 125 150 175 temperature in deg C -100 -75 -50 -25 0 25 50 75 100 output signal linearity deviation cubic fit |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |