57 / 84 page ![]() MPC5604P Microcontroller Data Sheet, Rev. 5 Preliminary—Subject to Change Without Notice Freescale Semiconductor 57 3.14 Flash memory electrical characteristics 5 This parameter includes the sample time t ADC_S. 6 20 MHz ADC clock. Specific prescaler is programmed on MC_PLL_CLK to provide 20 MHz clock to the ADC. 7 See Figure 16. Table 30. Program and erase specifications Symbol Parameter Min Value Typical Value1 1 Typical program and erase times assume nominal supply values and operation at 25 °C. All times are subject to change pending device characterization. Initial Max2 2 Initial factory condition: < 100 program/erase cycles, 25 °C, typical supply voltage. Max3 3 The maximum program & erase times occur after the specified number of program/erase cycles. These maximum values are characterized but not guaranteed. Unit Tdwprogram P Double Word (64 bits) Program Time4 4 Actual hardware programming times. This does not include software overhead. — 22 50 500 μs TBKPRG P Bank Program (512KB)4, 5 5 Typical Bank programming time assumes that all cells are programmed in a single pulse. In reality some cells will require more than one pulse, adding a small overhead to total bank programming time (see Initial Max column). — 1.45 1.65 33 s P Bank Program (64KB)4, 5 — 0.18 0.21 4.10 s T16kpperase P 16 KB Block Pre-program and Erase Time — 300 500 5000 ms T32kpperase P 32 KB Block Pre-program and Erase Time — 400 600 5000 ms T128kpperase P 128 KB Block Pre-program and Erase Time — 800 1300 7500 ms Table 31. Flash module life1 1 TBD: To be defined Symbol Parameter Conditions Value Unit Min Typ P/E C Number of program/erase cycles per block for 16 Kbyte blocks over the operating temperature range (TJ) — 100,000 — cycles P/E C Number of program/erase cycles per block for 32 Kbyte blocks over the operating temperature range (TJ) — 10,000 100,000 (TBC) cycles P/E C Number of program/erase cycles per block for 128 Kbyte blocks over the operating temperature range (TJ) — 1,000 100,000 (TBC) cycles Retention C Minimum data retention at 85 °C average ambient temperature2 Blocks with 0 – 1,000 P/E cycles 20 — years Blocks with 10,000 P/E cycles 10 — years Blocks with 100,000 P/E cycles 5— years |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |