9 / 27 page ![]() Combi PFC/ PWM Controller ICE1CS02 Functional Description Version 1.0 9 25 July 2008 3 Functional Description All values which are used in the functional description are typical values. For calculating the worst cases the min/max values which can be found in section 4 Electrical Characteristics have to be considered. 3.1 Introduction The ICE1CS02 comprises the complete control for power factor controlled switched mode power sup- plies. With its PFC and PWM section being internally synchronized, applies for off-line converters with input voltages ranging from 90 V to 270 V. The topology of the PFC preconverter is boost. The minimal line current gaps for the maximum duty cycle of the PFC is about 95%. The selectable maxi- mum duty of the PWM, however, is limited to 47% or 60% to prevent transformer saturation. The external RC-filter in the feedback line after the optocoupler is integrated into the IC in order to reduce the external component count. The Soft-Start function is integrated into the IC. An internal precise peak current control is integrated into the IC. With this function, the costs of the power transformer and the secondary rectifier diode can be reduced and the max power can also be limited. The maximum power is almost independent from the input voltage. Hence, it can avoid to over-size the critical components of the SMPS such as the power transformer or the secondary rectifier diode. 3.2 Power Management Figure 3 Power Management The Undervoltage Lockout monitors the external supply voltage VVCC. When the VVCC exceeds the on- threshold VCCon=12V, the internal bias circuit is switched on. A hysteresis sequence is implemented to avoid the uncontrolled rings during switch-on. The switch-off of the controller will take place when VVCC falls below 11V. The maximum current consumption before the controller is activated is around 1.3mA. When VVCC falls below the off-threshold; VCCoff=11.0V, the internal bias circuit is switched off . 3.3 Internal Synchronization Figure 4 Internal Synchronisation between PFC and PWM Out The clock rising edge will trigger a turn-off of PFC OUT and falling edge will trigger a turn-on of PWM OUT. Internal Bias Voltage Reference Power Management 5V VCC Undervoltage Lockout 12V 11V Power-Down Reset Soft start CLK OUT PFC OUT PWM OUT |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |