| поискавой системы для электроныых деталей |
|
ACT8740 датащи(PDF) 32 Page - Active-Semi, Inc |
|
|
|||||||||||||||||||||||||||||
ACT8740 датащи(HTML) 32 Page - Active-Semi, Inc |
|
32 / 40 page ![]() LOW-NOISE, LOW-DROPOUT, LINEAR REGULATORS ACT8740 Rev PrB, 25-Feb-08 Innovative Products. Active Solutions. - 32 - www.active-semi.com Copyright © 2008 Active-Semi, Inc. ActivePMU TM is a trademark of Active-Semi. I 2CTM is a trademark of Philips Electronics. General Description REG3, REG4, and REG5 are low-noise, low- dropout linear regulators (LDOs) that are optimized for low-noise and high-PSRR operation, achieving more than 60dB PSRR at frequencies up to 10kHz. LDO Output Voltage Programming All LDOs feature independently-programmable out- put voltages that are set via the I2C serial interface, increasing the ACT8740’s flexibility while reducing total solution size and cost. Set the output voltage by writing to the REG345CFG/VSETx[ ] registers. Output Current Capability REG3, REG4, and REG5 each supply 250mA of load current. Excellent performance is achieved over each regulator's entire load current ranges. Output Current Limit In order to ensure safe operation under over-load conditions, each LDO features current-limit circuitry with current fold-back. The current-limit circuitry limits the current that can be drawn from the output, providing protection in over-load conditions. For additional protection under extreme over current conditions, current-fold-back protection reduces the current-limit by approximately 30% under extreme overload conditions. Enabling and Disabling the LDOs All LDOs feature independent enable/disable con- trol via the I2C serial interface. Independently en- able or disable each output by writing to the appro- priate REG345CFG/ONx[ ] bit. Power-OK Each of the LDOs features Power-OK status bit that can be read by the system microprocessor via the I2C interface. If an output voltage is lower than the power-OK threshold, typically 6% below the pro- grammed regulation voltage, the corresponding REG345CFG/OKx[ ] will clear to 0. Reference Bypass Pin The ACT8740 contains a reference bypass pin which filters noise from the reference, providing a low-noise voltage reference to the LDOs. Bypass REF to G with a 0.01µF ceramic capacitor. Optional LDO Output Discharge Each of the ACT8740’s LDOs features an optional, independent output voltage discharge feature. When this feature is enabled, the LDO output is discharged to ground through a 1kΩ resistance when the LDO is shutdown. This feature may be enabled or disabled via the I2C interface by writing to the REG345CFG/DISx[ ] bits. Output Capacitor Selection REG3, REG4, and REG5 each require only a small ceramic capacitor for stability. For best perform- ance, each output capacitor should be connected directly between the OUTx and G pins as possible, with a short and direct connection. To ensure best performance for the device, the output capacitor should have a minimum capacitance of 1µF, and ESR value between 10mΩ and 200mΩ. High quality ceramic capacitors such as X7R and X5R dielectric types are strongly recommended. PCB Layout Considerations The ACT8740’s LDOs provide good DC, AC, and noise performance over a wide range of operating conditions, and are relatively insensitive to layout considerations. When designing a PCB, however, careful layout is necessary to prevent other circuitry from degrading LDO performance. A good design places input and output capacitors as close to the LDO inputs and output as possible, and utilizes a star-ground configuration for all regu- lators to prevent noise-coupling through ground. Output traces should be routed to avoid close prox- imity to noisy nodes, particularly the SW nodes of the DC/DCs. REFBP is a filtered reference noise, and internally has a direct connection to the linear regulator con- troller. Any noise injected onto REFBP will directly affect the outputs of the linear regulators, and therefore special care should be taken to ensure that no noise is injected to the outputs via REFBP. As with the LDO output capacitors, the REFBP by- pass capacitor should be placed as close to the IC as possible, with short, direct connections to the star-ground. Avoid the use of vias whenever possi- ble. Noisy nodes, such as from the DC/DCs, should be routed as far away from REFBP as possible. FUNCTIONAL DESCRIPTION |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |