| поискавой системы для электроныых деталей |
|
SW-456SMB датащи(PDF) 2 Page - M/A-COM Technology Solutions, Inc. |
|
|
|||||||||||||||||||||||||||||
SW-456SMB датащи(HTML) 2 Page - M/A-COM Technology Solutions, Inc. |
|
2 / 4 page ![]() GaAs SPDT Switch DC - 3.0 GHz Rev. V6 SW-456 • North America Tel: 800.366.2266 • Europe Tel: +353.21.244.6400 • India Tel: +91.80.43537383 • China Tel: +86.21.2407.1588 Visit www.macomtech.com for additional data sheets and product information. M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. 2 ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology Solutions is considering for development. Performance is based on target specifications, simulated results, and/or prototype measurements. Commitment to develop is not guaranteed. PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology Solutions has under development. Performance is based on engineering tests. Specifications are typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available. Commitment to produce in volume is not guaranteed. Electrical Specifications: TA = 25°C, VCTL = 0, -2.3 volts (unless otherwise specified) 3 3. External DC blocking capacitors are required on all RF ports when using positive voltage control. 4. Insertion loss can be optimized by varying the DC blocking capacitor value, e.g. 1000 pF for 100 MHz - 1 GHz, 39 pF for 0.5 - 3 GHz. Parameter Test Conditions Units Min. Typ. Max. Insertion Loss 4 DC - 1 GHz 1 - 2 GHz 2 - 3 GHz dB dB dB — — — 0.35 0.45 0.56 0.5 0.6 0.8 DC - 1 GHz 1 - 2 GHz 2 - 3 GHz dB dB dB 20 15 10 22 17 12 — — — VSWR DC - 3 GHz Ratio — 1.2:1 1.4:1 P1dB (2.3V supply) 500 MHz - 3 GHz dBm — 21 — P1dB (3V supply) 500 MHz - 3 GHz dBm — 27 — Input IP2 2-Tone 900 MHz, 5 MHz spacing (3.0 V) dBm — 81 — Input IP3 2-Tone 900 MHz, 5 MHz spacing (3.0 V) dBm — 52 — Trise, Tfall 10% to 90% RF, 90% to 10% RF ns — 25 — Ton, Toff 50% Control to 90% RF, Control to 10% RF ns — 25 — Transients In-Band mV — 25 — Control Current VCTL = -2.3 V µA — 4 15 Isolation Qualification Qualified to M/A-COM specification REL-201, Process Flow –2. Handling Procedures Please observe the following precautions to avoid damage: Static Sensitivity Gallium Arsenide Integrated Circuits are sensitive to electrostatic discharge (ESD) and can be damaged by static electricity. Proper ESD control techniques should be used when handling these devices. Truth Table Mode (Control) V1 V2 RFC - RF1 RFC - RF2 Positive 5 0 ± 0.2 V +2.3 to +8 V Off On +2.3 to +8 V 0 ± 0.2 V On Off 0 ± 0.2 V -2.3 V to -8 V On Off -2.3 V to -8 V 0 ± 0.2 V Off On Negative 6 5. External DC blocking capacitors are required on all RF ports. 1000 pF capacitors used for positive control voltage. For higher frequency operation, smaller value DC blocking capacitors can be substituted. 6. If negative control is used, DC blocking capacitors are not required on RF ports. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |