| поискавой системы для электроныых деталей |
|
RHT10 датащи(PDF) 5 Page - Extech Instruments Corporation. |
|
|
|||||||||||||||||||||||||||||
RHT10 датащи(HTML) 5 Page - Extech Instruments Corporation. |
|
5 / 11 page ![]() User Manual for Model RHT10 Version 1.3 March 2007 5 SETUP THE LOGGER Click on the computer icon on the menu bar (2 nd from left) or select LOGGER SET from the LINK pull-down menu. The Setup window will appear as shown below; descriptions for each field in the Setup window are listed directly below the illustration: The CURRENT TIME field will automatically synchronize with the PC date and time setting The MANUAL and INSTANT select buttons allow the user to start datalogging immediately when the Setup window is exited (INSTANT) or at a later time (MANUAL). Explained in the LOGGING READINGS section The LOGGER NAME field allows the user to select a unique name for the logger The SAMPLE POINTS field instructs the logger to take a finite number of readings The SAMPLE RATE pull-down menu instructs the logger to log readings at a specific rate The LED Flash Cycle can be set by the user (the longer the time, the longer the battery life) The ALARM SETTINGS portion of the SETUP window allows the user to set HIGH and LOW temperature/RH limits and disable the flashing of the Logger’s LEDs thereby conserving battery energy Click on the SETUP button to save changes. Press the DEFAULT button to set the Logger to factory default condition. Press the CANCEL button to abort the setup. LOGGING READINGS If INSTANT was selected in the SETUP window, the Logger begins logging at the instant the SETUP button is pressed. If MANUAL was selected, the Logger must be manually started by pressing and holding the Logger’s yellow button for approx. 3 seconds or until the two LEDs on the Logger flash at the same time. Logging will continue at the programmed sample rate until the number of readings (sample points) specified in the Setup window is reached. The green LED flashes once per sample point and the red LED flashes when user programmed alarm limits are exceeded. The yellow LED will flash at 10 second intervals AFTER the pre-determined number of readings has been logged. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |