| поискавой системы для электроныых деталей |
|
TMP112 датащи(PDF) 18 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
TMP112 датащи(HTML) 18 Page - Texas Instruments |
|
18 / 24 page ![]() USING THE SLOPE SPECIFICATIONS WITH A Power-Supply Level Contribution to Accuracy Accuracy = (V 3.3V) ± - ´ PSR S +0.250°C V (14) Accuracy = (1.8V 3.3V) ± - ´ PSR +0.250°C V =+0.375°C 0.8 0.6 0.4 0.2 0 0.2 0.4 0.6 - - - Temperature( C) ° Slope1 MAX Slope2 MAX Slope3 MAX Calibrationat+25 CRemovesOffset ° -40 -20 0 40 60 130 100 110 120 80 90 70 50 20 30 10 -30 -10 TMP112 SBOS473B – MARCH 2009 – REVISED JUNE 2009 ......................................................................................................................................................... www.ti.com Using the previous example temperature range of 1-POINT CALIBRATION 0°C to +50°C, the worst-case temperature error is now reduced to the worst-case slopes because the The initial accuracy assurance at +25°C with the offset at +25°C (that is, the maximum and minimum slope regions provides an accuracy that is high temperature errors of +0.3°C and –0.5°C) is removed. enough for most applications; however, if higher Therefore, a user can expect the worst-case accuracy accuracy is desired, this increase can be achieved to improve to +0.175°C. with a 1-point calibration at +25°C. This calibration removes the offset at room temperature, thereby reducing the source of error in a TMP112 temperature reading down to the curvature. Figure 20 The superior accuracy that can be achieved with the shows the error of a calibrated TMP112. TMP112 is complemented by its immunity to dc variations from a 3.3V supply voltage. This immunity is important because it spares the user from having to use another LDO to produce 3.3V to achieve accuracy. Nevertheless, the noise quantization that results from changing supply can add some slight change in temperature measurement accuracy. As an example, if the user chooses to operate at 1.8V, the worst-case expected change in accuracy can be calculated by Equation 14: (15) This example is a worst-case accuracy contribution Figure 20. Calibrated Accuracy and Slope Curves as a result of variation in power supply that should be versus Temperature added to the accuracy + slope maximum. 18 Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated Product Folder Link(s): TMP112 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |