| поискавой системы для электроныых деталей |
|
TMS320 датащи(PDF) 25 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TMS320 датащи(HTML) 25 Page - Texas Instruments |
|
25 / 69 page ![]() TMS32020 SPRS010B — MAY 1987 — REVISED NOVEMBER 1990 POST OFFICE BOX 1443 • HOUSTON, TEXAS 77001 25 RS, INT, BIO, AND XF TIMING switching characteristics over recommended operating conditions (see Note 3 and 8) PARAMETER MIN TYP MAX UNIT td(RS) CLKOUT1 low to reset state entered 45 ns td(IACK) CLKOUT1 to IACK valid – 25 0 25 ns td(XF) XF valid before falling edge of STRB Q – 30 ns NOTES: 3. Q = 1/4tc(C). 8. RS, INT, and BIO are asynchronous inputs and can occur at any time during a clock cycle. However, if the specified setup time is met, the exact sequence shown in the timing diagrams will occur. timing requirements over recommended operating conditions (see Note 3 and 8) MIN NOM MAX UNIT tsu(IN) INT/BIO/RS setup before CLKOUT1 high 50 ns th(IN) INT/BIO/RS hold after CLKOUT1 high 0 ns tf(IN) INT/BIO fall time 15† ns tw(IN) INT/BIO low pulse duration tc(C) ns tw(RS) RS low pulse duration 3tc(C) ns † Value derived from characterization data and not tested. NOTES: 3. Q = 1/4tc(C). 8. RS, INT, and BIO are asynchronous inputs and can occur at any time during a clock cycle. However, if the specified setup time is met, the exact sequence shown in the timing diagrams will occur. HOLD TIMING switching characteristics over recommended operating conditions (see Note 3) PARAMETER MIN TYP MAX UNIT td(C1L-AL) HOLDA low after CLKOUT1 low –25† 25 ns tdis(AL-A) HOLDA low to address three-state 15† ns tdis(C1L-A) Address three-state after CLKOUT1 low (HOLD mode, see Note 9) 30† ns td(HH-AH) HOLD high to HOLDA high 50 ns ten(A-C1L) Address driven before CLKOUT1 low (HOLD mode, see Note 9) 10† ns † Value derived from characterization data and not tested. NOTES: 3. Q = 1/4tc(C). 9. A15-A0, PS, DS, IS, STRB, and R/W timings are all included in timings referenced as “address.” timing requirements over recommended operating conditions (see Note 3) MIN NOM MAX UNIT td(C2H-H) HOLD valid after CLKOUT2 high Q – 45 ns NOTE 3: Q = 1/4tc(C). |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |