  TL780 Datasheet HTML 1Page - Texas Instruments TL780 Datasheet HTML 2Page - Texas Instruments TL780 Datasheet HTML 3Page - Texas Instruments TL780 Datasheet HTML 4Page - Texas Instruments TL780 Datasheet HTML 5Page - Texas Instruments TL780 Datasheet HTML 6Page - Texas Instruments TL780 Datasheet HTML 7Page - Texas Instruments TL780 Datasheet HTML 8Page - Texas Instruments  
Zoom Inzoom in Zoom Outzoom out
 6 / 8 page
background image
TL780 SERIES
POSITIVE-VOLTAGE REGULATORS
SLVS055F – APRIL 1981 – REVISED DECEMBER 1999
6
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
electrical characteristics, VI = 23 V, IO = 500 mA, TJ = 25°C (unless otherwise noted)
PARAMETER
TEST CONDITIONS†
TL780-15Y
UNIT
PARAMETER
TEST CONDITIONS†
MIN
TYP
MAX
UNIT
Output voltage
IO = 5 mA to 1 A,
P
≤ 15 W
15
V
Input voltage regulation
VI = 17.5 V to 30 V
1.5
mV
Input voltage regulation
VI = 20 V to 26 V
1.5
mV
Output voltage regulation
IO = 5 mA to 1.5 A
7
mV
Output voltage regulation
IO = 250 mA to 750 mA
2.5
mV
Output resistance
f = 1 kHz
0.0035
W
Output noise voltage
f = 10 Hz to 100 kHz
225
µV
Dropout voltage
IO = 1 A
2
V
Input bias current
5.5
mA
Short-circuit output current
230
mA
Peak output current
2.2
A
† Pulse-testing techniques maintain the junction temperature as close to the ambient temperature as possible. Thermal effects must be taken into
account separately. All characteristics are measured with a 0.33-
µF capacitor across the input and a 0.22-µF capacitor across the output.
PARAMETER MEASUREMENT INFORMATION
(see Note B)
C2 = 0.22
µF
(see Note A)
C1 = 0.33
µF
OUTPUT
(see Note C)
INPUT
C
O
I
TL780
NOTES: A. C1 is required when the regulator is far from the power-supply filter.
B. C2 is not required for stability; however, transient response is improved.
C. Permanent damage can occur when OUTPUT is pulled below ground.
Figure 1. Test Circuit



Html Pages

1 2 3 4 5 6 7 8


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com