BSDX Series
Signal conditioned high precision pressure transducers
1/5
February 2009 / 631
www.sensortechnics.com
FEATURES
· 0...25 mbar to 0...5 bar,
0...±10 mbar to 0...±1 bar,
barometric range 800...1100 mbar
· Absolute, gage or differential pressure
· 0.5 to 4.5 V ratiometric output
· Precision ASIC conditioning
· Temperature compensated
· Total accuracy ±0.5 to ±1.0 %FSS
SPECIFICATIONS
ELECTRICAL CONNECTION
Maximum ratings
Supply voltage V
S
4.75 V to 5.25 V
DC
max. 6.50 V
DC
Output current
Sink
2 mA
Source
2 mA
Lead temperature (2 - 4 sec.)
250°C
Temperature ranges
Compensated
0 to +85 °C
Operating
-20 to +105 °C
Storage
-40 to +125 °C
Vibration
10 g at 20 - 2000 Hz
Shock
100 g for 11 ms
Caution! The sensor is not reverse polarity protected.
Incorrect applications of excitation
voltage or ground to the wrong pin can
cause electrical failure.
Application of supply voltage above the
maximum can cause electrical failure.
BSDX
15 nF
220 nF
5
6
7
8
4
2
+Vs
Vout
GND
3
1
N/C
N/C
Note:
Capacitor 220 nF required
between +Vs and GND and
15 nF between Vout and GND.
It is important to place the
capacitors as close to the pins
as possible!
Pins 4, 5, 6, 7 and 8 are internal
device connections and should
not be connected for any reason!