2 / 2 page ![]() Q. What advantage does the RR2 have over the RR1? A. The RR2 has the ability to differentiate between continuous and pulsed panel outputs and can be used on single output panels. Q. What panel types are compatible with the RR2? A. The RR2 can be used with 2-wire, 4-wire, 12 VDC or 24 VDC single or combination output panels. Q. Does the RR2 operate with Ademco panels? Are separate Ademco modules also required? A. The RR2 operates with Ademco panels and does not require a separate Ademco module. Q. Does the RR2 operate with continuous and coded (pulsed) alarm signals? A. The RR2 offers a field-selectable switch for setting the RR2 for continuous or coded outputs. Q. Are there any special wiring instructions to follow with the RR2? A. Polarity should be observed and the RR2 must be connected to an auxiliary power supply. Q. What kind of panel outputs are required for use with the RR2? A. The RR2 can be used with fire control panels with a bell/alarm output or an alarm relay output. Q. Does the RR2 accommodate more than one 2-wire sounder detector (2100AT) on a loop? A. Yes, more than one model 2100AT can be placed on a zone when the panel switches to a reverse polarity, non- current-limited auxiliary power supply*. Refer to wiring diagrams below for specific 2-wire detector wiring. * Current supply must be adequate per appropriate calculations. ©2001 System Sensor. The company reser ves the right to change product specifications without notice. A05-0313-000•3/01(5K)•#733 Frequently Asked Questions System Sensor Sales and Service System Sensor Headquarters 3825 Ohio Avenue St. Charles, IL 60174 Ph: 800/736-7672 Fx: 630/377-6495 Documents-on-Demand: 800/736-7672 x3 Web: www.systemsensor.com System Sensor in Canada Ph: 905/812-0767 Fx: 905/812-0771 System Sensor in Europe Ph: + 44.1403.276500 Fx: + 44.1403.276501 System Sensor in China Ph: + 86.29.524.6253 Fx: + 86.29.524.6259 System Sensor in Singapore Ph: + 65.273.2230 Fx: + 65.273.2610 System Sensor in the Far East Ph: + 852.21919003 Fx: + 852.27366580 System Sensor in Australia Ph: + 613.54.281.142 Fx: + 613.54.281.172 System Sensor in India Ph: + 91.11.558.2119 Fx: + 91.11.527.6815 EOL + + – A + RA400Z A - + – BELL/ ALARM CIRCUIT (positive signal in alarm state) UL LISTED ALARM CONTROL PANEL INITIATING CIRCUIT PURPLE T+ + – + – AUX POWER YELLOW IN+ ORANGE IN– RED PWR+ BLACK PWR– BROWN OUT+ WHITE OUT– Power Not Used + + – A + RA400Z A - + – Power Not Used EOL + + – A + RA400Z A - + – ALARM RELAY (NO Contact) UL LISTED ALARM CONTROL PANEL INITIATING CIRCUIT + – + – AUX POWER Power Not Used + + – A + RA400Z A - + – Power Not Used PURPLE T+ YELLOW IN+ ORANGE IN– RED PWR+ BLACK PWR– BROWN OUT+ WHITE OUT– 2-Wire System Triggered from IAC/Bell Circuit: 2-Wire System Triggered from Alarm Relay Contact: NOTE: If optional Style A (Class A) wiring is used, a second RR2 module must be added to enable concurrent loop polarity reversal. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |