| поискавой системы для электроныых деталей |
|
LTC4101EG датащи(PDF) 21 Page - Linear Technology |
|
|
|||||||||||||||||||||||||||||
LTC4101EG датащи(HTML) 21 Page - Linear Technology |
|
21 / 28 page ![]() LTC4101 21 4101f OPERATIO Figure 8. Charging Current Waveform in Low Current Mode ILIMIT/8 AVERAGE CHARGER CURRENT 4101 F08 ~40ms 0 Figure 9. Adapter Current Limiting 100mV – + R1 4.99k CLP CLN INFET 4101 F09 LTC4101 C9 0.1 µF RCL* VIN CL1 *RCL = 100mV ADAPTER CURRENT LIMIT TO LOAD 24 23 4 the input FET is turned off slowly. If the voltage between DCIN and CLP is ever less than –25mV, then the input FET is turned off quickly to prevent significant reverse current from flowing in the input FET. In this condition the CHGEN pin is driven low and the charger is disabled. The AC Present Block (AC_PRESENT) The DCDIV pin is used to determine AC presence. If the DCDIV voltage is above the DCDIV comparator threshold (VACP), then the ACP output pin will be switched to VDD and the AC_PRESENT bit in the ChargerStatus() function will be set. If the DCDIV voltage is below the DCDIV compara- tor threshold minus the DCDIV comparator hysteresis, then the ACP output pin is switched to GND and the AC_PRESENT bit in the ChargerStatus() function is cleared. The ACP output pin is designed to drive 2mA continuously. Adapter Limiting An important feature of the LTC4101 is the ability to automatically adjust charging current to a level which avoids overloading the wall adapter. This allows the prod- uct to operate at the same time that batteries are being charged without complex load management algorithms. Additionally, batteries will automatically be charged at the maximum possible rate of which the adapter is capable. This feature is created by sensing total adapter output current and adjusting charging current downward if a preset adapter current limit is exceeded. True analog control is used, with closed loop feedback ensuring that adapter load current remains within limits. Amplifier CL1 in Figure 9 senses the voltage across RCL, connected between the CLP and CLN pins. When this voltage exceeds 100mV, the amplifier will override programmed charging current to limit adapter current to 100mV/RCL. A lowpass filter formed by 4.99k and 0.1 µF is required to eliminate switching noise. If the current limit is not used, CLP should be connected to CLP, but leave CLN connected to power. Setting Input Current Limit To set the input current limit, you need to know the minimum wall adapter current rating. Subtract 7% for the input current limit tolerance and use that current to deter- mine the resistor value. RCL = 100mV/ILIM ILIM = Adapter Min Current – (Adapter Min Current • 7%) As is often the case, the wall adapter will usually have at least a +10% current limit margin and many times one can simply set the adapter current limit value to the actual adapter rating (see Figure 9). |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |