13 / 20 page ![]() LTC4080X 13 4080Xf Timer and Recharge The LTC4080X’s battery charger has an internal charge termination timer that starts when the input voltage is greater than the undervoltage lockout threshold and at least 82mV above BAT, and the battery charger is leaving shutdown. At power-up or when exiting shutdown, the charge time is set to 4.5 hours. Once the charge cycle terminates, the battery charger continuously monitors the BAT pin voltage using a comparator with a 2ms filter time. When the aver- age battery voltage falls below 4.1V (which corresponds to 80%-90% battery capacity), a new charge cycle is initi- ated and a 2.25 hour timer begins. This ensures that the battery is kept at, or near, a fully charged condition and eliminates the need for periodic charge cycle initiations. The ⎯C⎯H⎯R⎯G output assumes a strong pulldown state dur- ing recharge cycles until C/10 is reached or the recharge cycle terminates. SWITCHING REGULATOR OPERATION: The switching buck regulator in the LTC4080X can be turned on by pulling the EN_BUCK pin above VIH. It has two user- selectable modes of operation: constant-frequency (PWM) mode and Burst Mode Operation. The constant-frequency mode operation offers low noise at the expense of efficiency whereas the Burst Mode operation offers higher efficiency at light loads at the cost of increased noise, higher output voltage ripple, and less output current. A detailed descrip- tion of different operating modes and different aspects of operation follow. Operations can best be understood by referring to the Block Diagram. Constant-Frequency (PWM) Mode Operation The switching regulator operates in constant-frequency (PWM) mode when the MODE pin is pulled below VIL. In this mode, it uses a current mode architecture including an oscillator, an error amplifier, and a PWM comparator for excellent line and load regulation. The main switch MP2 (P-channel MOSFET) turns on to charge the inductor at the beginning of each clock cycle if the FB pin voltage is less than the 0.8V reference voltage. The current into the inductor (and the load) increases until it reaches the peak current demanded by the error amp. At this point, the main switch turns off and the synchronous switch MN1 (N-channel MOSFET) turns on allowing the inductor current to flow from ground to the load until either the next clock cycle begins or the current reduces to the zero current (IZERO) level. Oscillator: In constant-frequency mode, the switching regulator uses a dedicated oscillator which runs at a fixed frequency of 2.25MHz. This frequency is chosen to minimize possible interference with the AM radio band. Error Amplifier: The error amplifier is an internally com- pensated transconductance (gm) amplifier with a gm of 65 µmhos. The internal 0.8V reference voltage is compared to the voltage at the FB pin to generate a current signal at the output of the error amplifier. This cur- rent signal represents the peak inductor current required to achieve regulation. PWM Comparator: Lossless current sensing converts the PMOS switch current signal to a voltage which is summed with the internal slope compensation signal. The PWM comparator compares this summed signal to determine when to turn off the main switch. The switch current sensing is blanked for ~12ns at the beginning of each clock cycle to prevent false switch turn-off. Burst Mode Operation Burst Mode operation can be selected by pulling the MODE pin above VIH. In this mode, the internal oscil- lator is disabled, the error amplifier is converted into a comparator monitoring the FB voltage, and the inductor current swings between a fixed IPEAK (~100mA) and IZERO (35mA) irrespective of the load current as long as the FB pin voltage is less than or equal to the reference voltage of 0.8V. Once VFB is greater than 0.8V, the control logic shuts off both switches along with most of the circuitry and the regulator is said to enter into SLEEP mode. In SLEEP mode, the regulator only draws about 20µA from the BAT pin provided that the battery charger is turned off. When the output voltage droops about 1% from its nominal value, the regulator wakes up and the inductor current resumes swinging between IPEAK and IZERO. The output capacitor recharges and causes the regulator to re-enter the SLEEP state if the output load remains light OPERATIO |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |