| поискавой системы для электроныых деталей |
|
PCF1C датащи(PDF) 2 Page - KOA Speer Electronics, Inc. |
|
|
|||||||||||||||||||||||||||||
PCF1C датащи(HTML) 2 Page - KOA Speer Electronics, Inc. |
|
2 / 6 page ![]() PAGE 2 OF 6 SS-02 R6 Bolivar Drive ■ P.O. Box 547 ■ Bradford, PA 16701 ■ USA ■ 814-362-5536 ■ Fax 814-362-8883 ■ www.koaspeer.com Specifications given herein may be changed at any time without prior notice. Please confirm technical specifications before you order and/or use. KOA SPEER ELECTRONICS, INC. 4. Applications and Ratings 5. Characteristics 1 Nominal Resistance Range 3.3 to 9.1 ohms 10 to 91 ohms 100 to 910 ohms 1k to 9.1k ohms 10k to 91k ohms 100k to 1M ohms Resistance Tolerance ± 10% ± 20% K M 0.3 1.0 3.0 3.0 3.0 3.0 Recommended Test Voltages (DC Volts) In the event of a difference in resistance readings attributable to the test voltage used, the specified test voltage listed below shall be used. Resistance to the nominal resistance should be in each resistance tolerance shown below. Resistance (Method 303) Characteristics Test Method No. Requirement (MIL-STD 202) Absolute Maximum Overload Voltage Resistance Tolerance Absolute Maximum Working Voltage Part Designation Absolute Maximum Pulse Voltage* Power Rating @ 70°C Minimum Dielectric Withstanding Voltage Resistance Range E-12 PCF1/2 PCF1 PCF2 0.5W 1.0W 2.0W 500V 700V 4.7Ω - 100KΩ 3.3Ω - 390KΩ 200V 300V 400V K: ±10% M: ±20% 400V 10kV 600V 14kV 800V 20kV Operating Temperature Range -40°C to +200°C * Resistance to pulse: change shall be ±5% of the pre-test values. 1 sec. ON, 1 second OFF, 20,000 cycles. The voltage is applied with maximum pulse voltage. 2 Resistors shall be maintained within ± 1°C at the ambient temperatures listed below. The use of forced circulating air is recommended to assure temperature stability and uniformity. Resistance measurements shall be made at each temperature 15 minutes after air temperature has stabilized at the specified temperature. The percent difference in resistance referred to the resistance at +25°C shall be computed with the following formula: Percent Resistance = (R-r) x 100 Where: R is the resistance at test temperature r is the resistance at +25°C Difference r -1300 ± 300ppm/°C Temperature Coefficient (Method 304) Sequence 1 2 3 4 5 +25°C -40°C +25°C +75°C +125°C Ambient Temperature SS-02 R6 6/20/07 3:37 PM Page 2 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |