| поискавой системы для электроныых деталей |
|
COREAI-AR датащи(PDF) 22 Page - Actel Corporation |
|
|
|||||||||||||||||||||||||||||
COREAI-AR датащи(HTML) 22 Page - Actel Corporation |
|
22 / 25 page ![]() CoreAI 22 v2.0 ADC Operation Control of the ADC within the AB macro in CoreAI is accomplished by APB reads and writes. After a power-up reset condition, the ADC will come out of its reset state and commence with its internal calibration sequence. When this calibration sequence has finished, the ADC will be ready to use for conversions. Read the INT[1:0] register bits to obtain status information relevant to the ADC calibration. The user must configure the analog quads appropriately via the ACM interface to match the required design-specific voltage, current, and temperature ranges prior to performing ADC conversions; failure to do so may result in damage to the Fusion device. The SmartGen software can be used to configure the analog quads and RTC. ADC Control A typical analog-to-digital conversion is shown starting in Figure 7 and ending in Figure 8 on page 23. The steps for performing an ADC conversion are as follows: 1. Read the ADC Status register to ensure that the ADC is not busy calibrating or performing a conversion. 2. Write the desired ADC settings to ADC Control register 1, including the voltage reference selection (internal or external), mode selection (ADC resolution), and clock divider settings. 3. Write the desired ADC settings to ADC Control register 2, including the sample time control and channel number to sample (1 of 32). 4. Set the Start Conversion bit to begin the conversion process. 5. If a current or temperature monitor operation is used on a corresponding AC or AT input pin, a write must be done to set the corresponding current or temperature monitor strobe high in ADC Control register 3 or ADC Control register 4, respectively. Refer to the Fusion datasheet for details on external component connection requirements for current and temperature monitoring. 6. Keep reading the high-order ADC Status register until the ADC is not busy performing a conversion. 7. If a current or temperature monitor operation has completed using a corresponding AC or AT input pin, a write must be done to set the corresponding current or temperature monitor strobe low in ADC Control register 3 or ADC Control register 4, respectively. 8. Read the low-order ADC Status register to obtain the lower 8 bits of the resulting ADC conversion data (the upper 4 bits of conversion data have already been read from the high-order ADC Status register). Note: 8-bit APB reads and writes are shown. Figure 7 • ADC Start of Conversion PCLK PADDR[4:0] PWRITE PSEL PENABLE PWDATA[7:0] PRDATA[7:0] ADCStat(hi) ADCCtrl1(lo) ADCCtrl1(hi) ADCCtrl2(lo) ADCCtrl2(hi) ADCStat(hi) 00 01 08 11 00 60 ADC Conversion Starts |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |