12 / 17 page ![]() 4 Functional Description L9826 12/17 CD00002120 4.4 Diagnostics The output voltage at all outputs is compared with the diagnostic threshold, typ 0,38 · VCC. Outputs 1 and 2 features dedicated fault latches. The output status signal is filtered and latched. The fault latches are cleared during NCS low. The latch stores the status bit, so the first reading after the error occurred might be wrong. The second reading is right. Table 6. Diagnostic Table for outputs 1 and 2 in parallel controlled mode: Fault condition 1) "output short circuit to Vbat" : the output was switched on and the voltage at the output exceeds the diagnostics threshold. The output operates in current regulation mode or has been switched off due to thermal shutdown. The status bit is low. Fault condition 2) "open load" or "output short circuit to GND" : the output is switched off and the voltage at the output drops below the diagnostics threshold, because the load current is lower than the output diagnostic current source, the load is interrupted. The diagnostic bit is low. For outputs 3 to 8 the output status signals, are fed directly to the SPI register. Table 7. Diagnostic Table for outputs 1 to 8 in SPI controlled mode: The fault condition 1) "output short circuit to Vbat" : the output was switched on and the voltage at the output exceeded the diagnostics threshold due to overcurrent, the output overload latch was set and the output has been switched off. The diagnostic bit is high. Fault condition 2) "open load" or "output short circuit to GND" is the same as of outputs 1 and 2. At the falling edge of NCS the output status data are transferred to the shift register. When NSC is low, data bits contained in the shift register are transferred to SDO output et every rising CLK edge. Output 1, 2 Output-voltage Status-bit Output-mode off > DG-threshold high correct operation off < DG-threshold low fault condition 2) on < DG-threshold high correct operation on > DG-threshold low fault condition 1) Output 1 ... 8 Output-voltage Status-bit Output-mode off > DG-threshold high correct operation off < DG-threshold low fault condition 2) on < DG-threshold low correct operation on > DG-threshold high fault condition 1) |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |