| поискавой системы для электроныых деталей |
|
M65762FP датащи(PDF) 13 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
M65762FP датащи(HTML) 13 Page - Renesas Technology Corp |
|
13 / 35 page ![]() M65762FP REJ03F0235-0200 Rev.2.00 Sep 14, 2007 Page 13 of 34 d7 (MP): Indication of pause at time of marker code detection (0: Indication of continuation/restart, 1: Indication of temporary pause) If this MP bit is in advance set to 1 in decoding, the decoding temporarily pauses at the time of marker code detected. (When the ME bit is set to 1, an interruption occurs when marker code is detected.) When decoding process is not completed at time of temporary pause of marker detection, the register for setting the number of lines can be respecified (see item (7)). Afterwards, setting this MP bit to 0 restarts the decoding process (the decoding process is carried out for the number of set lines). (6) Register for setting the number of pixels (W/R) (Address: 4) d7 d0 PEL_REG_L: PEL_L (Address: 5) PEL_REG_H: 0 PEL_H d7 d5 d0 d0 to 7 (PEL_L): Sets the number of pixels in a line. (Low byte) d0 to 5 (PEL_H): Sets the number of pixels in a line. (Upper byte) A maximum of 8192 pixels can be set at the 3-line template. A maximum of 10240 pixels can be set at the 2-line template. Set the number of pixels to be actually coded (decoded) at time of scale-up (scale-down). When the image data bus is 16 bits (32 bits) with the parallel I/F selected, set the number of pixels to multiples of 16 (multiples of 32). With the serial I/F selected, set the number of pixels to multiples of 8. (7) Register for setting the number of lines (W/R) (Address: 6) d7 d0 LSET_REG_L: LSET_L (Address: 7) LSET_REG_H: LSET_H d0 to 7 (LSET_L): Sets the number of lines to be processed. (Low order byte) (1 to 65535: 0 line is not allowed.) d0 to 7 (LSET_H): Sets the number of lines to be processed. (High order byte) At time of scale-down (scale-up), set the number of lines to be actually coded (decoded). Set the number of lines (number of relative lines) ranging from the processing start command to be issued next to the temporary stop/termination end just after. This register must be set to a specific value before the issuance of the process start command. As far as the following conditions are satisfied, this register can be rewritten in the course of processing. • When the maximum value (65535) is set before issuance of the processing start command, an arbitrary value can be set once in the course of processing. • When a value except for the maximum value (65535) is set before issuance of the processing start command, and the value requires to be respecified in the course, respecify the maximum value (65535) once and then respecify a desired value. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |