Back Button STPIC44L02 Datasheet HTML 9Page - STMicroelectronics STPIC44L02 Datasheet HTML 10Page - STMicroelectronics STPIC44L02 Datasheet HTML 11Page - STMicroelectronics STPIC44L02 Datasheet HTML 12Page - STMicroelectronics STPIC44L02 Datasheet HTML 13Page - STMicroelectronics STPIC44L02 Datasheet HTML 14Page - STMicroelectronics STPIC44L02 Datasheet HTML 15Page - STMicroelectronics STPIC44L02 Datasheet HTML 16Page - STMicroelectronics STPIC44L02 Datasheet HTML 17Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 13 / 21 page
background image
STPIC44L02
13/21
The STPIC44L02 monitors the drain voltage of
each channel to detect shorted load conditions.
The onboard deglitch timer starts running when
the gate output to the power FET transitates from
the off state to the on state. The timer provides a
60
µs deglitch time, t
(STBFM), toallow thedrain
voltage to stabilize after the power FET has been
turned on (see figure 16 and 17).
The deglitch delay time is only enabled for the first
60
µs after the FET has been turned on. After the
deglitch delay time, the drain voltage is checked to
verify that it is less than the fault reference
voltage. When it is greater than the reference
voltage for at least the short to battery deglitch
time, t(STBDG) FLT flags the microcontroller that a
fault
condition
exists
and
gate
output
is
automatically shut off until the error condition has
been corrected.
An overheating condition on the FET occurs when
the controller continually tries to reenable the
output under shorted load fault conditions. When a
shorted load fault is detected, the gate output is
transitated into a low duty cycle PWM signal to
protect the FET from overheating. The PWM rate
is defined as t(SB) and the pulse width is defined
as tW. The gate output remains in this state until
the fault has been corrected or until the controller
disables the gate output.
The microcontroller can read the serial port on the
predriver to isolate the channel that reported the
fault condition.
Fault bits 0-3 distinguish faults for each of the
output channels. When a shorted load occurs, the
STPIC44L02 automatically retries the output and
the fault clears after the fault condition has been
corrected. Figure 16 illustrates operation after a
gate output has been turned on. The gate to the
power FET is turned on and the deglitch timer
starts running. Under normal operation, T1 turns
on and the drain operates below the reference
point set at U1. The output of U1 is low and a fault
condition is not flagged.
Figure 14 : Open Load Test Circuit



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com