| поискавой системы для электроныых деталей |
|
L6376 датащи(PDF) 13 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L6376 датащи(HTML) 13 Page - STMicroelectronics |
|
13 / 18 page ![]() L6376 Demagnetization of inductive loads 13/18 11 Demagnetization of inductive loads The device has four internal clamping diodes able to demagnetize inductive loads. The limitation is the peak power dissipation of the packages, so — if the loads are big or if there is the possibility to demagnetize more loads contemporarly — it is necessary to use external demagnetization circuits. In Figure 7 and Figure 8 are shown two topologies for the demagnetization versus ground and versus VS. The breakdown voltage of the external device (VZ) must be chosen considering the minimum internal clamping voltage (Vcl) and the maximum supply voltage (VS). Figure 6. Input comparator hysteresis Figure 7. External demagnetization circuit (versus ground) Vi Vs Vout 100mV D94IN131 1.25V 100mV DRIVER VCP VS OVC O4 O3 O2 O1 D94IN109 RS SHORT CIRCUIT CONTROL UV CURRENT LIMIT VZ VZ < Vcl (min) - VS (max) |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|