| поискавой системы для электроныых деталей |
|
ST24LC21B датащи(PDF) 16 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ST24LC21B датащи(HTML) 16 Page - STMicroelectronics |
|
16 / 22 page ![]() BYTE WRITE CONTROL BYTE WORD ADDR DATA PAGE WRITE WORD ADD n DATA n DATA n + 1 AI01894 ACK ACK ACK ACK ACK ACK VCLK/WC CONTROL BYTE DATA n + 7 ACK ACK Figure 12. Inhibited Write when VCLK/WC = 0 – Step 1: the Master issues a START condition followed by a Device Select byte (1st byte of the new instruction). – Step 2: if the memory is busy with the internal write cycle, no ACK will be returned and the master goes back to Step 1. If the memory has terminated the internal write cycle, it will respond with an ACK, indicating that the mem- ory is ready to receive the second part of the instruction (the first byte of this instruction was already sent during Step 1). Read Operations On delivery, the memory content is set at all "1’s" (or FFh). Current Address Read. The memory has an inter- nal byte address counter. Each time a byte is read, this counter is incremented. For the Current Ad- dress Read mode, following a START condition, the master sends the Device Select code with the RW bit set to ’1’. The memory acknowledges this and outputs the data byte addressed by the internal byte address counter. This counter is then incre- mented. The master must NOT acknowledge the data byte output and terminates the transfer with a STOP condition. Random Address Read. A dummy write is per- formed to load the address into the address counter, see Figure 14. This is followed by a Re- START condition send by the master and the De- vice Select code is repeated with the RW bit set to ’1’. The memory acknowledges this and outputs the addressed data byte. The master must NOT ac- knowledge the data byte output and terminates the transfer with a STOP condition. Sequential Read. This mode can be initiated with either a Current Address Read or a Random Ad- dress Read. However, in this case the master DOES acknowledge the data byte output and the memory continues to output the next byte in se- quence. To terminate the stream of bytes, the master must NOT acknowledge the last data byte output, and MUST generate a STOP condition. The output data is from consecutive byte ad- dresses, with the internal byte address counter automatically incremented after each byte output. After a count of the last memory address, the address counter will ’roll-over’ and the memory will continue to output data. Acknowledge in Read Mode. In all read modes the ST24xy21 wait for an acknowledge during the 9th bit time. If the master does not pull the SDA line 16/22 ST24LC21B, ST24LW21, ST24FC21, ST24FC21B, ST24FW21 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |