| поискавой системы для электроныых деталей |
|
AJ71QC24N-R2 датащи(PDF) 14 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
AJ71QC24N-R2 датащи(HTML) 14 Page - Omron Electronics LLC |
|
14 / 24 page ![]() 14 EJ1 Connection External Connection • Functional insulation is applied between the power supply and the I/O sections. If reinforced insulation is required, connect the input and output terminals to devices without any exposed current-carrying parts or to devices with reinforced insulation suitable for the maximum operating voltage of the power supply and I/O sections. • To comply with the standards for noise terminal voltage for class A in EN 61326, install a noise filter (Densei Lamda MXB-1206-33 or the equivalent) to the DC power line as close as possible to the Temperature Controller. • Use an SELV power supply that provides overcurrent protection. An SELV circuit is one separated from the power supply with double insulation or reinforced insulation, that does exceed an output voltage of 30 V r.m.s. and 42.4 V peak or 60 VDC max. The OMROM S8VS Series is recommended for the power supply. EJ1N-TC4 EJ1N-HFU @-NFL@ EJ1C-EDUA Model with Screw Terminals EJ1N-TC2 EJ1N-HFUB-DRT DeviceNet Connector EJ1C-EDUC Model with Connector Terminal Block Note: 1. To connect to the G3ZA, separately purchase a G3ZA Connecting Cable (EJ1C-CBLA050) and connect it to the G3ZA connection port (CN1) on the EJ1. 2. To connect to a computer using the port A connector, use a separately sold E58-CIFQ1 USB-Serial Conversion Cable. The Temperature Controller can be connected to a computer using USB. 3. Models with screw-less clamp terminals have terminals A10 and B10, but they are not used. Do not connect anything to them. 12 VDC 12 VDC OUT4 OUT3 12 VDC 12 VDC OUT2 OUT1 B1 B2 B3 B4 B5 B6 B7 B8 B9 A1 A2 A3 A4 A5 A6 A7 A8 A9 CH4 CN1 G3ZA connection port Analog input Pt Thermo- couple A B B mA V CH3 A B B mA V CH2 A B B mA V CH1 A B B mA V RS-485 RS-422 Not used Not used Not used SUB2 SUB1 RS-232C RS-422 SD RD SG B1 B2 B3 B4 B5 B6 SUB4 SUB3 B7 B8 B9 B ( +) A ( −) RDB ( +) RDA ( −) SDB ( +) SDA ( −) A1 A2 A3 A4 A5 A6 A7 A8 A9 Port C Port C RS-485 for port C and RS-232C can be switched. A separate EJ1 model must be used for RS-422 communications. EV2 EV1 EV4 EV3 Port A connector B (+) A ( −) B (+) A ( −) + − RS-485 RS-485 1 2 3 4 5 6 7 8 9 Input power supply 24 VDC Port B Port A These two ports cannot be used at the same time. These terminals are used for distributed placement of Units when an HFU is used. SUB2 SUB1 OUT4 OUT3 B1 B2 B3 B4 B5 B6 12 VDC Models with pulse outputs Models with linear outputs 12 VDC B7 B8 B9 CN1 OUT2 OUT1 4 to 20 mA DC/0 to 20 mA 4 to 20 mA DC/0 to 20 mA OUT2 OUT1 A1 A2 A3 A4 A5 A6 EV2 EV1 A7 A8 A9 CT2 CT1 G3ZA connection port CH2 A B B mA V CH1 A B B mA V Analog input Pt Thermo- couple Not provided on models with linear output. Provided only on models with pulse output. V+ CAN H CAN L V − Power line Communications line, high Shield Communications line, low Power line These two ports cannot be used at the same time. These terminals are used for distributed placement of Units when an HFU is used. RS-485 RS-485 1 2 3 4 5 6 7 8 9 10 SUB2 SUB1 B (+) A ( −) B (+) A ( −) + − Input power supply 24 VDC Port A connector Port B Port A |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |